5.
Install four Torx-head mounting screws (Itron Part Number SCR-0010-005) as shown below. Hand
tighten each screw.
6.
Connect the ERT module wires to the register screw terminals following the 100WP-R pulser to the
Elster/AMCO meter register wire connections, (see
Connecting 100WP-R to a Remote Meter Register
on
page 9). After connecting the wires, carefully tuck the connectors into the ERT module housing. Tighten
all screws securely.
Caution
Install the wires around the screws in a clockwise direction (as shown) or the wires may come
out from under the screw heads as you tighten them. Also, verify insulation is
NOT
compressed under the
screw head, or the wire may not make good contact.
7.
Install the module and mounting bracket on the meter register adapter collar.
8.
Replace the hollow pin (1) you removed in step 1.