![ITRON 100W-R Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/itron/100w-r/100w-r_installation-manual_2095983035.webp)
Installing the 100W-R and 100WP-R ERT Modules
TDC-0951-005 100W-R and 100WP-R Datalogging ERT Module Installation Guide
30
Proprietary and Confidential
To install the 100W-R and 100WP-R ERT modules to a Badger Direct-Mount register
Caution
Verify you have a Badger meter with a register designed for direct mount ERT modules.
Check the part number on the label to verify the module matches the meter.
Always install the module with the arrow on the housing pointing upward.
Note
The register may or may not be mounted on the meter when performing the following steps.
1.
Direct-meter mounting requires a 100W-R ERT module for the Badger ADE register or a 100WP-R for
the RTR register. Both ERTs have three wires:
(1)
brown insulated wire
(2)
yellow insulated wire
(3)
gray insulated wire
Note
For an RTR register, tuck the unused yellow wire into the housing.