International Thermal Research
15
Section 4,
Installing the Fuel
System
4.1
Before You Begin
For efficient and safe operation of The WindowWasher™ by
ITR, follow all recommendations for properly installing the
fuel system. Any deviations from these recommendations
must be approved in advance by Calcutt Boats or ITR.
Never use petrol in The WindowWasher™ by ITR. Use only
diesel fuel, furnace oil, stove oil or kerosene.
Keep fuel lines away from any heat source above 100°F
(38°C).
Keep petrol and any equipment that uses petrol away from
The WindowWasher™ by ITR location. The
WindowWasher™ by ITR is not rated for use in an explosive
environment.
Never share the fuel supply to The WindowWasher™ by ITR
with any other fuel-burning device.
4.2
Fuel System Installation
Recommendation for Installation
The WindowWasher™ by ITR’s fuel connections are accessed
from the front panel of the heater. The fuel inlet and fuel
return are labelled and located on the front lower face of The
WindowWasher™ by ITR and are not interchangeable. These
fittings consist of 1/8” female NPT that connect to the fuel
pump inside the units’ front cover.
The following is recommended for the fuel system
installation:
Section
4
! DANGER
! WARNING