BIDIRECTIONAL LEVEL ITW
USER MANUAL
18
6.1. GENERAL SPECIFICATIONS FOR DIGITAL LEVEL ITW 4/4
MASTER / SLAVE:
Power
230Vac or 12Vdc stabilized
Max. consumption in Stand by 9.2W - 230Vca / 135mA – 12Vdc
Max. consumption in emission 13.8W - 230Vca / 1.335A – 12Vdc
Configuration:
4 digital inputs (potential-free).
4 digital outputs through relay of 16Amp.
1 Relay of incidence
LCD
Display inputs, outputs and incidences.
Presentation
polyamide box with 30% fiberglass, size 250*195*100 mm
6.2. GENERAL SPECIFICATIONS FOR DIGITAL LEVEL ITW 8/8
MASTER / SLAVE:
Power
230Vac or 12Vdc stabilized
Max. consumption in Stand by 9.4W - 230Vca / 232mA – 12Vdc
Max. consumption in emission 14W - 230Vca / 1.432A – 12Vdc
Configuration:
8 digital inputs (potential-free).
8 digital outputs through relay of 16Amp.
1 Relay of incidence
LCD
Display inputs, outputs and incidences.
Presentation
polyamide box with 30% fiberglass, size 250*195*100 mm
6.3. GENERAL SPECIFICATIONS FOR DIGITAL/ANALOG LEVEL ITW 4/4AD
MASTER / SLAVE:
Power
230Vac or 12Vdc stabilized
Max. consumption in Stand by 9.2W - 230Vca / 220mA – 12Vdc
Max. consumption in emission 13.8W - 230Vca / 1.420A – 12Vdc
Configuration:
4 digital inputs (potential-free).
4 digital outputs through relay of 16Amp.
1 Relay of incidence
MASTER
4 analogical inputs (resolution 12 bits)
configurable by jumpers 0-20mA / 4-20mA / 0-5V / 0-10V
SLAVE
4 analogical outputs (resolution 12 bits)
configurable (in factory) 0-20mA / 4-20mA / 0-5V / 0-10V
LCD
Display inputs, outputs and incidences.
Presentation
polyamide box with 30% fiberglass, size 250*195*100 mm
Содержание SINDITO
Страница 1: ...BIDIRECTIONAL LEVEL ITW USER MANUAL USER MANUAL BIDIRECTIONAL LEVEL ITW SET...
Страница 4: ...BIDIRECTIONAL LEVEL ITW USER MANUAL...
Страница 11: ...BIDIRECTIONAL LEVEL ITW USER MANUAL 7 POWER SUPPLY Connection...
Страница 16: ...BIDIRECTIONAL LEVEL ITW USER MANUAL 12 3 1 2 LINK BETWEEN VARIOUS POINTS...
Страница 17: ...BIDIRECTIONAL LEVEL ITW USER MANUAL 13 3 2 CONNECTION DIAGRAM OF THE ANTENNA WITH THE COAXIAL CABLE RG 213...