Itowa IT3R10 Скачать руководство пользователя страница 4

RECEIVER IT3R10 

USER MANUAL 
 



1. INTRODUCTION 

 

The manual you have in your hands is a guide for the correct use of the multi-frequency receiver IT3R10.  

This receiver, together with the associated remote control, has been specifically designed for the wireless 
remote control of electromechanically operated machinery. 

The  radio  signals  used  employ  FM  frequency  modulation  and  FFSK  encoding.  The  most  advanced 
technology and the latest generation microprocessors have been used in electronic design. 

To  avoid  unwanted  operations,  the  receiver  is  provided  with  various  security  mechanisms  that  will  be 
described in the next chapters. Any auto-detection of anomalies blocks the execution of operations. 

The  type  of  transmission  used,  GCFI  (Intelligent  Changing  Frequency  Management)  provides  the 
equipment  with  an  intelligent  system  enabling  it  to  change  to  vacant  frequencies  automatically  and  at 
random, thereby avoiding interferences which could cause continuous downtimes during operation. 

The  receiver  works  in  the  UHF  band  at  frequencies  between  433,050  and  434,775  MHz  or  between 
868,000 and 870,000 MHz as prescribed in telecommunications regulations I-ETS 300 220. 

Contact Itowa for other certificates. 

 

2. GENERAL TERMS FOR THE CORRECT AND SAFE USE OF RADIO  
REMOTE CONTROL

 

 

For  maximum  safety  when  handling  the  radio  control,  the  user  must  follow  the  rules  indicated  in  this 
manual. 

Whenever  the  crane  has  to  be  manoeuvred,  the  radio  control  operator  must  be  in  a  place  where  he  can 
view the whole manoeuvre being performed. If this is not possible, he should position himself where he can 
see  as  much  of  the  manoeuvre  as  possible,  and  coordinate  with  another  person  when  he  cannot  see 
properly. Never perform a manoeuvre which may be partially uncontrolled. 

When  the  operator  finishes  his  work  on  the  receiver,  he  must  activate  the  emergency  stop  (STOP 
BUTTON)  of  the  transmitter  and  must  take  care  not  to  leave  the  machine  control  accessible  to 
unauthorized personnel. 

Содержание IT3R10

Страница 1: ...User Manual MARI10EN Rev 1 05 2020 Receiver IT3R10 EN nS...

Страница 2: ...RODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITO...

Страница 3: ...RECEIVER 5 4 TECHNICAL SPECIFICATIONS 6 5 INSTALLATION AND START UP 7 5 1 INSTALLATION OF THE RECEIVER 7 5 1 1 FASTENING OPTIONS 7 5 2 CONNECTING 7 5 3 START UP 9 6 MAINTENANCE 10 6 1 MAINTENANCE OF...

Страница 4: ...y and at random thereby avoiding interferences which could cause continuous downtimes during operation The receiver works in the UHF band at frequencies between 433 050 and 434 775 MHz or between 868...

Страница 5: ...for each operation of the crane FM radio modulation and FFSK coding are used for radio transmission of control signals The control module is in charge of verifying that the information received is fr...

Страница 6: ...2 A to 250 Vac or 30 Vdc Power supply according to the model 48 Vac 230 Vac 20 15 according to EN 60047 5 1 48 Vac 115 Vac 20 15 seg n EN 60047 5 1 115 Vac 230 Vac 20 15 seg n EN 60047 5 1 24 Vac 230...

Страница 7: ...na it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS For the magnetic fastening option it should be placed on a met...

Страница 8: ...ATION AT TERMINALS 24 AND 26 1 This relay can be configured as N C Normally Close through the bridge located on the back of the board 2 For other power supplies please see the attached documents provi...

Страница 9: ...lowing steps will be done with the transmitter associated with the receiver Insert a charged battery into the transmitter set release the STOP BUTTON and press the START 1 button The remote control wi...

Страница 10: ...BEFORE HANDLING THE TRANSMITTER TURN OFF THE GENERAL SWITCH OF THE MACHINE 6 1 MAINTENANCE OF THE RECEIVER During maintenance of the receiver the following parts will be checked The connection between...

Страница 11: ...rting with LED S1 with the first digit of the code reading from left to right The following table indicates the correspondence between the hexadecimal value of each digit and the number of flashes tha...

Страница 12: ...STATE LED S2 Stand by mode or operation without changes Fault in Stop relays Flashing for each change of state in one of the relays STATE LED S3 Not used STATE LED S4 EEPROM Ok Error in EEPROM STATE...

Страница 13: ...to the electrical panel of the machine using the corresponding connectors The set is connected to the machine but it does not work The power supply of the set is under 45 of the nominal value The set...

Страница 14: ...ns avoiding possible negative consequences for the environment resulting from improper disposal And also allows a treatment and recycling of the materials that compose it obtaining important savings i...

Страница 15: ...RECEIVER IT3R10 USER MANUAL 15 www itowa com SINDITO S L Faraday 159 08224 Terrassa Barcelona Espa a Tel 34 93 733 98 50...

Отзывы: