Itowa IT3R10 Скачать руководство пользователя страница 11

RECEIVER  IT3R10 

 USER MANUAL 

 

11 



7.  DISPLAY THE EQUIPMENT CODE 

 

The  code  of  the  equipment  is  a  unique  hexadecimal  code  shared  between  the  transmitter  and  the 
receiver, and identifies and links them by radio frequency.  

In case you need to know the equipment code, the receiver allows its display by acting on 

jumper J1

 on 

the motherboard.  

To start the display, place the

 jumper

 in the position indicated in the following image: 

 

 

Detail of jumper J1 to show the equipment code 

 

At  this  point,  starts  the  code  display  sequence  through  the  LED,  The  value  in  hexadecimal  of  each 
number will be represented by a LED on the front panel of the receiver by a number of flashes equal to 
that value, starting with LED S1 with the first digit of the code (reading from left to right). 

The  following  table  indicates  the  correspondence  between  the  hexadecimal  value  of  each  digit  and  the 
number of flashes that will correspond to the LED that represents it. 

 

 Code character (

Hexadecimal value

0  1  2  3  4  5  6  7  8  9 

 Number of  pulses (

Decimal value

0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15 

 

Note once the  receiver  detects  the  position of jumper  J1, the functional  test of all LEDs  begins, without 
interruption. Between the presentation of one LED and another, all the LEDs flash as a separation mark. 
If  the  position  of  jumper  J1  is  changed  during  the  test,  the  sequence  is  not  interrupted.  For  a  better 
understanding of this process, we propose an example of code and the result of its display. 

 With the example code 01A38E you get: 

 

LED 

S1  S2  S3  S4 

 

 

Code 

Nº of pulses  LED 

10 

14 

Содержание IT3R10

Страница 1: ...User Manual MARI10EN Rev 1 05 2020 Receiver IT3R10 EN nS...

Страница 2: ...RODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITO...

Страница 3: ...RECEIVER 5 4 TECHNICAL SPECIFICATIONS 6 5 INSTALLATION AND START UP 7 5 1 INSTALLATION OF THE RECEIVER 7 5 1 1 FASTENING OPTIONS 7 5 2 CONNECTING 7 5 3 START UP 9 6 MAINTENANCE 10 6 1 MAINTENANCE OF...

Страница 4: ...y and at random thereby avoiding interferences which could cause continuous downtimes during operation The receiver works in the UHF band at frequencies between 433 050 and 434 775 MHz or between 868...

Страница 5: ...for each operation of the crane FM radio modulation and FFSK coding are used for radio transmission of control signals The control module is in charge of verifying that the information received is fr...

Страница 6: ...2 A to 250 Vac or 30 Vdc Power supply according to the model 48 Vac 230 Vac 20 15 according to EN 60047 5 1 48 Vac 115 Vac 20 15 seg n EN 60047 5 1 115 Vac 230 Vac 20 15 seg n EN 60047 5 1 24 Vac 230...

Страница 7: ...na it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS For the magnetic fastening option it should be placed on a met...

Страница 8: ...ATION AT TERMINALS 24 AND 26 1 This relay can be configured as N C Normally Close through the bridge located on the back of the board 2 For other power supplies please see the attached documents provi...

Страница 9: ...lowing steps will be done with the transmitter associated with the receiver Insert a charged battery into the transmitter set release the STOP BUTTON and press the START 1 button The remote control wi...

Страница 10: ...BEFORE HANDLING THE TRANSMITTER TURN OFF THE GENERAL SWITCH OF THE MACHINE 6 1 MAINTENANCE OF THE RECEIVER During maintenance of the receiver the following parts will be checked The connection between...

Страница 11: ...rting with LED S1 with the first digit of the code reading from left to right The following table indicates the correspondence between the hexadecimal value of each digit and the number of flashes tha...

Страница 12: ...STATE LED S2 Stand by mode or operation without changes Fault in Stop relays Flashing for each change of state in one of the relays STATE LED S3 Not used STATE LED S4 EEPROM Ok Error in EEPROM STATE...

Страница 13: ...to the electrical panel of the machine using the corresponding connectors The set is connected to the machine but it does not work The power supply of the set is under 45 of the nominal value The set...

Страница 14: ...ns avoiding possible negative consequences for the environment resulting from improper disposal And also allows a treatment and recycling of the materials that compose it obtaining important savings i...

Страница 15: ...RECEIVER IT3R10 USER MANUAL 15 www itowa com SINDITO S L Faraday 159 08224 Terrassa Barcelona Espa a Tel 34 93 733 98 50...

Отзывы: