Itowa CTN Скачать руководство пользователя страница 20



MINI RECEIVER

         

USER'S MANUAL 

 

14 

 

 

6. MAINTENANCE OF THE RECEIVER

 

The receiver you have purchased is made of top quality materials that ensure perfect operation and 

functionality.  Like  any  other  machine  or  device,  this  receiver  requires  a  few  basic  attentions  that 

should be satisfied. In order to increase the useful life of your receiver as much as possible, and to 

avoid  unnecessary  repair  costs,  we  strongly  recommend  you  to  follow  the  following  conservation 

and maintenance tips: 

•  Use the mounting accessories properly and adjust them in a way that the use of the receiver 

is comfortable and safe. 

•  Avoid unnecessary impacts. 
•  It is advisable not to leave the receiver unnecessarily exposed to the sunlight. 

 

ATTENTION!   

ORIGINAL  SPARE  PARTS  MUST  BE  USED  FOR  ANY  REPAIR  AND 

UNDER  NO  CONCEPT  SHOULD  THE  SECURITY  CHARACTERISTICS 

OF THE RECEIVER BE ALTERED. 

For the maintenance of the receiver, the following parts must be checked: 

•  The connection between the receiver and the machine's electrical system. 
•  The correct operation of the active and passive safety circuits. 
•  The correct operation of all the LEDs through the start-up test. 
•  Correct closing of the receiver cover and packing gland (Model CTN). 
•  The firm subjection of the whole assembly. 
•  If you have an external antenna, check that the connection is clean and free of rust. 

In order to check the functioning of the active safety, it will be enough to activate the EMERGENCY 
STOP on the transmitter while it’s running. The general contactor must fall immediately. 

To  check  the  function  of  the  passive  safety,  disconnect  the  power  supply  or  battery  of  the 

transmitter. The general contactor should fall out after no more than 1.9 seconds. 

Содержание CTN

Страница 1: ...USER S MANUAL MINI RECEIVER...

Страница 2: ......

Страница 3: ...A IS STRICTLY PROHIBITED OTHERWISE ITOWA RESERVES THE RIGHT TO TAKE IN ACCORDANCE WITH CURRENT LEGISLATION THE ACTIONS IT CONSIDERS APPROPRIATE ITOWA RESERVES THE RIGHT TO MODIFY THIS MANUAL WITHOUT N...

Страница 4: ......

Страница 5: ...L FIXATION 8 5 1 2 CPH MODEL FIXATION 9 5 2 CONNECTION 10 5 2 1 CTN MODEL CONNECTION 10 5 2 2 CPH MODEL CONNECTION 11 5 3 POWER SUPPLY 12 5 4 START UP 12 6 MAINTENANCE OF THE TRANSMITTER 13 7 DISPLAY...

Страница 6: ......

Страница 7: ...afety mechanisms which will be described in the following chapters Any auto detection of anomalies blocks the execution of manoeuvres The transmitter works in the UHF band with frequencies between 433...

Страница 8: ...e he has vision at all times of the maneuver he is carrying out If this is impossible to achieve the operator must be in a place that allows him to see the maximum possible maneuver and in hidden plac...

Страница 9: ...m The following diagram is for GCFI versi n Fig 3 2 Receiver Block Diagram GCFI The signal captured by the antenna is injected to the receiver which supplies the microprocessor with a low frequency si...

Страница 10: ...of the receiver For extra security all surveillance circuits are doubled 3 2 CTN MODEL This is a watertight assembly IP65 protection made of a highly resistant plastic material It contains the control...

Страница 11: ...r similar protected from external agents and from humidity and dirt The mounting system of the transmitter standard DIN 35 rail does not require any adaptation process simply place it on the rail and...

Страница 12: ...time 1900 ms Range of action 90 meters Temperature range From 20 to 70 C Frequency Bands UHF UN 30 from C N A F 434 050 to 434 775 MHz UHF UN 32 from C N A F 433 050 to 434 775 MHz UHF UN 39 from C N...

Страница 13: ...230 Vac 20 15 according to EN 60047 5 1 115 Vac 20 15 according to EN 60047 5 1 48 Vac 20 15 according to EN 60047 5 1 24 Vac 20 15 according to EN 60047 5 1 24 Vdc 20 15 according to EN 60047 5 1 12...

Страница 14: ...towa connector Dimensions 190 x 83 x 165mm Weight With fixation 800gr Fixation By bolts DIN rail or magnetic optional Protection IP65 4 2 CPH MODEL Connection Via accessible terminal block Dimensions...

Страница 15: ...ine in issue especially in its accessibility and transit areas to the points where the operator must perform his work In applications with external antennas the antenna should be free of metal shields...

Страница 16: ...gnetic force of the magnets to uninstall the device make lever with a flat screwdriver between the metal structure of the machine and the magnetic fixation 5 1 2 CPH MODEL FIXATION Figure 5 2 CPH mode...

Страница 17: ...cted to the receiver at one end through the Itowa terminal strip supplied for the CTN model or to the terminal block for the CPH model while at the other end a multi pin connector will be placed ident...

Страница 18: ...MINI RECEIVER USER S MANUAL 12 5 2 2 CPH MODEL CONNECTION Figure 5 4 CPH model connection...

Страница 19: ...T UP Once the receiver has been installed when the main switch of the machine is activated the LEDs of the receiver unit will light up as a test When starting up the transmitter the receiver will star...

Страница 20: ...ST BE USED FOR ANY REPAIR AND UNDER NO CONCEPT SHOULD THE SECURITY CHARACTERISTICS OF THE RECEIVER BE ALTERED For the maintenance of the receiver the following parts must be checked The connection bet...

Страница 21: ...PERATION OF THE RECEIVER THE RECEIVER MUST BE IMMEDIATELY SWITCHED OFF ATTENTION BEFORE ANY MANIPULATION PROCEED TO DEACTIVATE THE GENERAL SWITCH OF THE MACHINE For any doubt or query do not hesitate...

Страница 22: ...TOP to switch to the rest state At that moment the receiver will indicate the working channel using the leds First the led will flash as many times as the frequency channel has tens When the display o...

Страница 23: ...nvenient to configure one of them to avoid these anomalies While the receiver is at rest it performs a scan of the free and occupied channels of the whole band If the scanned channel is busy it will c...

Страница 24: ...Service The receiver is not connected to the machine Connect the hose from the receiver to the machine s control panel using the appropriate connectors The receiver is connected to the machine but sti...

Страница 25: ...o reset Antenna disconnected broken or in poor condition Replace the antenna or contact the Technical Support Service Even if the transmitter is disconnected by locking the EMERGENCY STOP the receiver...

Страница 26: ...o frequency signal Interference shutdown Receiver at rest STATUS LED Rx Receiver at rest Radio frequency signal recognized as own Radio frequency signal NOT recognized as own Error in radiofrequency r...

Страница 27: ...MINI RECEIVER USER S MANUAL 21 Icon Description Led off Slow flashing of led Led off with fast blinking on Led on with rapid blinking off Led on...

Страница 28: ...ing possible negative consequences for the environment caused by inadequate disposal and allows treatment and recycling of the materials that constitute it obtaining significant savings in energy and...

Отзывы: