26
Transfers product(s) from upstream in group to
downstream, when the adjacent downstream
zone is empty. This mode drives the present
and all the upstream zones having product in.
Set the SW1 #4 (ZPA mode) to ON.
HBV-609 Technical documentation
ZPA mode settings
7.
Control/Operation
7-1.
ZPA mode settings
SW1#4
(
OFF
)
ON
1 2 3 4 5 6 7 8
Singulated release Mode
SW1#4
(
ON
)
ON
1 2 3 4 5 6 7 8
Slug (train) release Mode
・
ZPA
:
Zero Pressure Accumulation
・
ZONE
Function to prevent the collision between products by
creating a consistent space by a decentralized control.
A zone is consisted of 1 MDR connecting multiple free
rollers.
STOP
STOP
1 zone
Term
Transfers product from upstream one by one to
downstream, when the adjacent downstream
zone is empty.
Set the SW1 #4 (ZPA mode) to OFF.
(Default setting)
Card with no communication cable
connected is identified as
downstream end, and the zone
drive stops by the sensor detection
in the zone.
■
Card with no communication cable
connected is identified as
downstream end, and the zone
drive stops by the sensor detection.
■
Present zone won’t discharge
product in case adjacent
downstream zone has failure.
■
■
Present zone won’t discharge
product in case adjacent
downstream zone has failure.
RUN
:
A product in the present zone is discharged to the downstream.
STOP
:
A product remains in the present zone.
EMPTY
:
Present zone is empty and ready to receive a product.
MDR
STOP
Transfer direction
Transfer direction
STOP
RUN
EMPTY
STOP
STOP
STOP
RUN
STOP
RUN
EMPTY
EMPTY
RUN
STOP
RUN
STOP
STOP
EMPTY
STOP
1
2
3
1
2
MDR
S
S
S
S
S
S
S
S
S
S
S
S
sensor
S
S
S
S
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
S
S
S
S
sensor
Singulated release Mode
Slug (train) release Mode