background image

WATER PUMP OPERATOR’S MANUAL

GENERAL SAFETY RULES

Before operating, ensure you have read and understood the manual and operational procedures to help 
reduce the risk of damage to your product as well as potential personal injury.

Before operating, perform the pre-operation inspection to make the use of your water pump safe.

Under no circumstances should you use your pump for flammable or corrosive liquids (such as petrol 
or acid). To prolong the life of your water pump, do not use for corrosive liquids such as salt water, 
chemical solutions or alkaline liquids.

Locate the water pump on a firm and level ground, a slopped or overturned water pump may result in 
the spilling of oil and fuel.

Always operate your pump outdoors in a well ventilated area away from any potentially flammable or 
hazardous material. NEVER run your water pump indoors or in a shed, exhaust emissions from the 
engine contain toxic carbon monoxide (CO) which can lead to death if inhaled.

Keep children and pets away from the pump when in use.

Always fill the petrol tank with the water pump turned off and in a well ventilated area. After filling, 
ensure the fuel cap is tightened correctly and you wipe any excess/spilled fuel from the top of the fuel 
tank.

4

www.itmtools.com.au

Содержание TM530-050

Страница 1: ...ols com au Ver 1 3 OPERATOR S MANUAL PETROL WATER PUMPS MODELS TM530 050 TM530 080 TM530 250 TO PREVENT SERIOUS INJURY OR DAMAGE TO YOUR WATER PUMP READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BE...

Страница 2: ...bility pursuant to this guarantee for the costs of travelling or transportation of the product or parts to and from ITMS or the service agent or dealer such costs are not included in this warranty Our...

Страница 3: ...nderstand the content of this manual for safety guidelines start up priming operation adjustment and maintenance instructions before using this product Take all possible precautions to protect your ow...

Страница 4: ...hemical solutions or alkaline liquids Locate the water pump on a firm and level ground a slopped or overturned water pump may result in the spilling of oil and fuel Always operate your pump outdoors i...

Страница 5: ...tion are in the API label on the o container We recommend that you use API SERVICE category SJ oil The recommended operating range of this pump is 23 F to 104 F 5 C t 40 C AIR FILTER CLEANING A dirty...

Страница 6: ...se must be reinforced with a non collapsible wall or braided construction Do not use a hose smaller than the pump s suction port size Minimum hose size DS20 1 2 in 50 mm DS30 3 in 80 mm DS40 4 in 100...

Страница 7: ...f the way FAST position FUEL VALVE LEVER ON CHOKE LEVER CLOSED SLOW THROTTLE LEVER 15 4 Turn the ignition switch to the ON position 5 Pull the recoil starter grip lightly untilresistance is felt then...

Страница 8: ...fresh water Allow the water to drain from the pump chamber then reinstall the filler cap and drain plug IGNITION SWITCH OFF SLOW OFF FUEL LEVEL 17 2 Turn the ignition switch to the OFF position 3 Turn...

Страница 9: ...l servicing of the engine and pump should be done by an authorised dealer who has the correct tools and is qualified mechanically For any engine maintenance please refer to the Honda Engine owners man...

Страница 10: ...spark plug Spark plug wet with fuel flooded engine Dry and reinstall spark plug 4 Take engine to an authorized servicing dealer or refer to shop manual Fuel filter clogged carburetor malfunction ignit...

Страница 11: ...and discharge head Excessive head Relocate pump and or hoses to reduce head 4 Check engine Engine lacks power Low Pump Output Possible Cause Correction 1 Check suction hose Hose collapsed damaged too...

Отзывы: