background image

 Page 9 of 16 

AT400 User Manual 
Rev 2.0 

Jan. 05

-201

7

Input Current (with all options):  

 

10-30VDC: 

AT400: 22mA, TAT420: 43mA 

  110VAC: 

AT400: 19mA, TAT420: 21mA 

  220VAC: 

AT400: 10mA, TAT420: 11mA 

Output Impedance (0-1V and 0-5V outputs): 

  1K

Ω

 

Enclosure: 

 

ABS plastic, NEMA Class 4 

Dimensions: 

  Housing: 

4.8” x 4.8” x 2.2” 

  Probe: 

1” or 2 ¾” diameters 

Weight: 

18 ounces 

Options: 

  Custom cable lengths: 

For probe cables

1

 

Included: 

(1) AT400 Instrument

(1) Vane-type probe head, choice of AP100 or AP275

(1) Probe connection cable, 5 ft. for AP275

NOTE: If a longer cable is ordered, the 5ft. is not included.

(1) AT400 operation manual

Certificate of Calibration with Data

www.

.com

[email protected]

1.800.561.8187

Содержание Kanomax AT400

Страница 1: ...Page 1 of 16 AT400 User Manual Rev 2 0 Jan 05 2017 Model AT400 User Manual www com information itm com 1 800 561 8187...

Страница 2: ...ensitive and are not user serviceable Opening the cases by a non authorized service center and or in a non ESD safe environment may cause damage not covered by the manufacturer s warranty Important Ma...

Страница 3: ...olybrominated biphenyls and polybrominated diphenyl ethers 0 01 by weight in homogenous materials for cadmium Please be advised that we do not analyze for these substances WEEE Waste Electrical and El...

Страница 4: ...fore applying power Power may still be present after voltage has been removed via storage in the capacitors Only authorized repairs can be accomplished after proper discharging of the circuits CAUTION...

Страница 5: ...fy or repair the product Failure to observe the above may cause damage to the instrument or the probe It may also void the manufacturer s warranty and calibration certificate Do not pick up or carry t...

Страница 6: ...recorder printer and meter or control circuit Every instrument has terminals for both DC and AC power and 0 1V 0 5V and 4 20mA outputs The outputs are concurrent and can accept multiple wires dependin...

Страница 7: ...Probe 1 0 C TAT420 Transmitter Air Velocity 0 02 mA Transmitter Temperature 0 10 mA TAT420 Response Time Air Velocity 2 second average and update Temperature TAT420 Approximately 60 seconds Analog Ou...

Страница 8: ...ABS plastic NEMA Class 4 Dimensions Housing 4 8 x 4 8 x 2 2 Probe 1 or 2 diameters Weight 18 ounces Options Custom cable lengths For probe cables1 Included 1 AT400 Instrument 1 Vane type probe head ch...

Страница 9: ...cables Attach in location free of physical dangers such as excessive heat or continuous condensing moisture 2 Note On the AT400 terminals 1 3 are not be installed Note Terminals 13 15 are not install...

Страница 10: ...ground reference to slot 7 Then hook the air velocity output wire to slot 5 2c 4 20mA F S output hook output ground reference to slot 7 Then hook the air velocity wire to slot 4 TEMPERATURE OUTPUT TA...

Страница 11: ...2 0 Jan 05 2017 METRIC OR ENGLISH UNITS Shown on the diagram but no longer available REPLACING COVER Use care not to damage the seal DISPLAY SWITCH Shown on the diagram but no longer available www com...

Страница 12: ...n screws above slots when finished Diagram 1 Location and Polarity of Connectors and Switches Air velocity Connector Display Connector 1 2 3 5 4 330 11 cm 3 515 8 93 cm Calibration Jumper J1 6 4 Tempe...

Страница 13: ...ength cables for air probes with temperature sensors must be ordered at the time the transmitter is purchased or the unit must be returned for calibration 2 Cable grips will seal on round cables from...

Отзывы: