ILS-S810-0IR
DOC-S810-0IR-MNL Rev1.doc (9/22/2021)
Page 18 of
18
Copyright 2021 ITL, LLC
Appendix A – Troubleshooting
1. If the ILS-S810 will not turn on at night:
a. Ensure the light is located in a dark environment (below 30 foot candles).
b. Ensure that the unit has been exposed to direct sunlight for at least 30
minutes to activate by checking that LED I3 is blinking every 5 seconds.
c. Ensure that the battery is above the shutdown voltage.
2. If the ILS-S810 will not turn off during the day:
a. Ensure that the solar panel cable is connected inside the ILS-S810.
3. If the ILS-S810 does not respond to the Infrared Remote Control:
a. Ensure that the ILS-S810 is on by exposing it to direct sunlight for up to 40
minutes. LED I3 will blink once every 5 seconds when the unit is on.
b. Replace the battery in the Infrared Remote Control.
4. If the ILS-S810 begins flashing at night when flashing is disabled this indicates an
extremely low battery condition.
a. See section Battery Replacement.
Revision
Description of Change
Date
Preparer / Approval
0
Initial Release
3/3/2021
Prepared By: Elke Hinson
Approved By: Andy Rudolph
1
Updated Title, added “SOLARIS”.
9/22/2021
Prepared By: Elke Hinson
Approved By: Andy Rudolph