ILS-S810-0IR
DOC-S810-0IR-MNL Rev1.doc (9/22/2021)
Page 16 of
18
Copyright 2021 ITL, LLC
Lens Replacement
1. Remove the lens screws from the lens and fixture body (HDW-2520-125S).
2. Disconnect the battery cable and solar panel cable.
3. Remove the PCB screws (HDW-0424-31S-TR).
4. Place PCB in new lens ensuring that the PCB orientation hole is aligned with the
lens orientation indicator stud.
5. Replace PCB screws.
6. Reconnect the battery cable and solar panel cable.
7. Replace lens on body and secure with lens screws.
(see figure 8 for more details).
Figure 8: Lens Assembly