Troubleshooting
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Vacuum will not stop
Hose improperly inserted
into vacuum inlet
Ensure that the hose
end is properly placed
in the vacuum inlet: the
tab on the hose should
fit into the slots of the
inlet, to ensure adequate
contacts for the hose
switch to function (see
page 14).
Defective on/off hose
If the hose is properly
placed in the vacuum
inlet, and the unit
continues running
despite the fact that
the hose switch is in
the “off” position, have
the hose checked by a
service center.
Low voltage wire is not
connected properly
While vacuum is on,
unplug low voltage
wires from unit. If
vacuum stops, there’s a
faulty low voltage wire.
Contact your installer
or authorized service
center.
If in spite of these suggestions, your vacuum unit is still not stopping,
contact your authorized service center.
Note: Press the hose switch for one full second to shut off central vacuum.