Wipe instrument after use with a soft, clean cloth.  If instrument is soiled, use a non-abrasive, neutral detergent on 
a damp cloth to clean it.  Always store the instrument in a protective case. 
 

NOTE:  DO NOT IMMERSE INSTRUMENT IN LIQUID. 

 

C

LEANING OF 

O

PTICS

 

 
Should cleaning of external surfaces be necessary, blow off dust with a triple-filtered, high pressure optical quality 
dusting spray.  Wipe surface with a clean cotton swab moistened with laboratory grade alcohol.  Excess alcohol 
can be blown away with the spray. 
 

ITI Model 126110 RVI Cleaning Kit may be used. 

 

P

RECAUTIONS

 

 
Do not use beyond recommended temperatures: 
 

Maximum 150° F (65° C) 

Minimum   32° F (0° C) 

 
Do not allow instrument to contact live or exposed wiring.  It is an excellent conductor. 
 
 
 

R

EPAIR 

P

OLICY

 

 
If your equipment requires factory attention, contact ITI’s Customer Service Dept. at (413) 562-3606 for a Return 
Authorization Number.  Please be prepared to furnish your model and serial numbers.  Return the equipment to 
ITI, freight prepaid. 
 
Ship to: 

Instrument Technology, Inc. 

33 Airport Road 

Westfield, MA  01085-1357 

 

Please note Return Authorization Number on Purchase Orders, and all shipping documents.  

 
Upon receipt of your equipment, ITI will assess its condition to determine if repairs are needed.  If repairs are 
required, we will quote repair costs and a schedule for repairs.  Your options at this point are: 
 

1)  Accept Repair 

 
To proceed with the repair, ITI will require a purchase order for the full quoted repair price. 

 

2)  Decline Repair - Upgrade to a New Instrument 

 
Choosing this option requires a purchase order for the new equipment at its quoted price.  ITI will ship out the 
next available unit. 
 

3)  Decline Repair 

 
Please Note - Most repair evaluations require a partial or complete disassembly of the equipment.  

Once 

disassembled, it is impossible to return it to the customer in “as received” condition.

  At the 

customer's option, ITI will either return your equipment in its disassembled state, or dispose of it. 

Содержание 175180

Страница 1: ...field MA 01086 33 Airport Road Westfield MA 01085 Tel 413 562 3606 Fax 413 568 9809 Email iti scopes com www scopes com INSTRUMENT TECHNOLOGY INC OPERATION MANUAL MODEL 175180 FLASHLIGHT ILLUMINATOR WHITE LIGHT IR ...

Страница 2: ...ology Inc Feel free to contact ITI or your local ITI Representative with any questions WARRANTY Instrument Technology Inc warrants that the equipment is fit for the purposes described herein for a period of one year after the date of shipment when used in accordance with the directions for use and agrees to repair or replace any such defective component part at no cost to the customer There are no...

Страница 3: ...located at the base of the Battery Handle to turn On the light source Depress the Power Switch again to turn Off the light source LAMP REPLACEMENT WHITE LIGHT HEAD The White Light Head has a spare Lamp conveniently located in the base of the Lamp Holder Assembly To access the Lamp first use pliers to gently pull the Lamp Holder Assembly out of the head CAUTION LAMP MAY BE HOT ALLOW IT TO COOL BEFO...

Страница 4: ...urn Authorization Number Please be prepared to furnish your model and serial numbers Return the equipment to ITI freight prepaid Ship to Instrument Technology Inc 33 Airport Road Westfield MA 01085 1357 Please note Return Authorization Number on Purchase Orders and all shipping documents Upon receipt of your equipment ITI will assess its condition to determine if repairs are needed If repairs are ...

Отзывы: