ITI 135310 Скачать руководство пользователя страница 9

I

NSTRUMENT 

C

ARE

 

 

C

LEANING 

A

FTER 

U

SE

 

 
Wipe instrument after use with a soft, clean cloth.  If instrument is soiled, use a non-abrasive, neutral detergent on 
a damp cloth to clean it.  Always store the instrument in a protective case. 
 

NOTE:  DO NOT IMMERSE INSTRUMENT IN LIQUID. 

 

C

LEANING OF 

O

PTICS

 

 
Should cleaning of external surfaces be necessary, blow off dust with a triple-filtered, high pressure optical quality 
dusting spray.  Wipe surface with a clean cotton swab moistened with laboratory grade alcohol.  Excess alcohol 
can be blown away with the spray. 
 
ITI Model 126110 RVI Cleaning Kit may be used. 
 

C

LEANING OF 

M

IRROR

 

 
THE MIRROR SURFACE ON THE RIGHT ANGLE ADAPTER SHOULD 

NEVER BE TOUCHED

.  TOUCHING 

THE MIRROR WILL CAUSE SCRATCHES THAT WILL DETERIORATE THE IMAGE QUALITY. 
 
Blow off dust with a triple-filtered, high pressure optical quality dusting spray.  Flush with alcohol to remove debris. 
 
ITI Model 126110 RVI Cleaning Kit may be used. 
 

P

RECAUTIONS

 

 
Do not use beyond recommended temperatures: 

Maximum 150° F (65° C) 

Minimum   32° F (0° C) 

 
Do not allow instrument to contact live or exposed wiring.  It is an excellent conductor. 
 

R

EPAIR 

P

OLICY

 

 
If your equipment requires factory attention, contact ITI’s Customer Service Dept. at (413) 562-3606 for a Return 
Authorization Number.  Please be prepared to furnish your model and serial numbers.  Return the equipment to 
ITI, freight prepaid.  Ship to: 

Instrument Technology, Inc. 

33 Airport Road 

Westfield, MA  01085-1357 

 

Please note Return Authorization Number on Purchase Orders, and all shipping documents. 

 
Upon receipt of your equipment, ITI will assess its condition to determine if repairs are needed.  If repairs are 
required, we will quote repair costs and a schedule for repairs.  Your options at this point are: 
 

1) Accept 

Repair 

 

To proceed with the repair, ITI will require a purchase order for the full quoted repair price. 

 

2)  Decline Repair - Upgrade to a New Instrument 

 

Choosing this option requires a purchase order for the new equipment at its quoted price.  ITI will ship out the 
next available unit. 

 

3) Decline 

Repair 

 

Please Note - Most repair evaluations require a partial or complete disassembly of the equipment.  

Once 

disassembled, it is impossible to return it to the customer in “as received” condition.

  At the 

customer's option, ITI will either return your equipment in its disassembled state, or dispose of it. 

Содержание 135310

Страница 1: ...estfield MA 01086 33 Airport Road Westfield MA 01085 Tel 413 562 3606 Fax 413 568 9809 Email iti scopes com www scopes com INSTRUMENT TECHNOLOGY INC OPERATION MANUAL MODEL 135310 UNDER DOOR REMOTE VIE...

Страница 2: ...ear after the date of shipment when used in accordance with the directions for use and agrees to repair or replace any such defective component part at no cost to the customer There are no other expre...

Страница 3: ...e carefully inserted under a doorway Never use the RVI to pry door If there is insufficient space to insert blade of scope use a Uni Bar to gently lift door then insert blade The Uni Bar is an availab...

Страница 4: ...to re establish clear focus RIGHT ANGLE ADAPTER Slide Right Angle Adapter onto the blade with mirror facing up until it clicks in place Note that the image reverts left right when using this adapter U...

Страница 5: ...ch ITI Model 126070 41mm Visual Adapter to the back of the Eyepiece 3 Remove lens from ITI Model 135630 NVPS Screw NVPS onto the back of the Visual Adapter Remove protective cap from NVPS and attach r...

Страница 6: ...the NVPS relay lens to the ITI Model 135630 NVPS lens will only adapt one way 4 If using a 1 2 format CCD camera just simply screw on the camera For use with 1 3 CCD cameras use the C Mount Extender s...

Страница 7: ...tter Plate by black plastic housing flat side down Slide distal end of plate underneath door 2 Slide or pivot Infrared Emitter Plate around to vary intensity of Infrared light emitted into room 3 To d...

Страница 8: ...age Not Clear Dirt on external optical surfaces Clean optics Scope not focused Focus scope Dirt or liquid on internal optical surfaces Return to ITI for repair 1 3 CCD without C Mount Extender Use C M...

Страница 9: ...exposed wiring It is an excellent conductor REPAIR POLICY If your equipment requires factory attention contact ITI s Customer Service Dept at 413 562 3606 for a Return Authorization Number Please be...