ITI 135310 Скачать руководство пользователя страница 3

O

PERATING 

I

NSTRUCTIONS

 

 

O

VERVIEW OF 

A

PPLICATIONS

 

 
ITI Model 135310 Under Door Remote Viewing Kit employs a unique probe intended for covert surveillance.  The 
scope’s 3.5” or 7.0” long blade is structured to allow surveillance into an adjacent room by utilizing the ¼” space 
available under most doorways.   
 
The Right Angle Viewing Adapter allows the user to view behind doors to search for obstacles and/or barricades.   
Optional accessories, Infrared Emitter Kit , Night Vision Scope and video cameras can be used in low or no light 
situations. 
 
This kit is intended to provide maximum resolution, portability and quick setup, and also features a dedicated “C”  
mount for video camera attachment. 
 

I

NSTALLATION 

& M

OUNTING

 

CAUTION

 

 
BORESCOPES ARE DELICATE GLASS INSTRUMENTS, AND SHOULD BE TREATED ACCORDINGLY.  
PROPER HANDLING AND CLEANING TECHNIQUES WILL GREATLY INCREASE THE LIFE OF THIS 
INSTRUMENT.  ONLY TRAINED OPERATORS SHOULD HANDLE THIS EQUIPMENT.  

DO NOT BEND

 

OR 

APPLY UNNECESSARY STRESS. 
 

U

NDER

-D

OOR 

RVI I

NSERTION

 

 
The working length blade of this instrument is made from a hardened tool steel.  Although it is designed to 
withstand normal field use for its intended application, the probe should never be forced. 
 
The ¼” space available under most doorways allows sufficient clearance to utilize this instrument.  With the scope 
fully assembled, for visual or video use, the blade should be carefully inserted under a doorway.  Never use the 
RVI to pry door.  If there is insufficient space to insert blade of scope, use a Uni-Bar to gently lift door,  then insert 
blade.  The Uni-Bar is an available item for purchase from ITI. 
 
For initial insertion, the operator should view through the scope, using either eyepiece of monitor, to insure that a 
clear insertion path is available.  If any obstructions are noticed, try another location. 
 
It is also recommended that the initial insertion be performed without the Right Angle Adapter.  This will allow for a 
better view to assess the condition within the room. 
 
After the room has been fully viewed, the Right Angle Adapter can be used to observe the inside surface of the 
door.  This is especially useful to detect for locks, braces or barricades. 
 
For low, or no, light situations, optional accessories are available.  Night Vision Scopes or low light video cameras 
greatly enhance low light scenes.  The Infrared Emitter Kit also enhances the performance of Night Vision Scope 
for extremely dark rooms. 
 

C

AMERA 

C

ONNECTION

 

 
A standard “C” mount is supplied on the rear of the RVI.  For use with 1/3" CCD cameras, use the "C" Mount 
Extender supplied with the camera.  Screw camera onto the “C” mount or “C” Mount Extender until it bottoms out. 
 
ITI recommends a 1/3” format CCD for use with this RVI.  A 1/2” format CCD can also be used, although the 
monitor image will be quite small.  ITI suggests the 1/2” format low light CCD camera with NVPS. 
 
To obtain an upright image on the monitor, hold RVI stationary and rotate rear knob and camera together 

 

Содержание 135310

Страница 1: ...estfield MA 01086 33 Airport Road Westfield MA 01085 Tel 413 562 3606 Fax 413 568 9809 Email iti scopes com www scopes com INSTRUMENT TECHNOLOGY INC OPERATION MANUAL MODEL 135310 UNDER DOOR REMOTE VIE...

Страница 2: ...ear after the date of shipment when used in accordance with the directions for use and agrees to repair or replace any such defective component part at no cost to the customer There are no other expre...

Страница 3: ...e carefully inserted under a doorway Never use the RVI to pry door If there is insufficient space to insert blade of scope use a Uni Bar to gently lift door then insert blade The Uni Bar is an availab...

Страница 4: ...to re establish clear focus RIGHT ANGLE ADAPTER Slide Right Angle Adapter onto the blade with mirror facing up until it clicks in place Note that the image reverts left right when using this adapter U...

Страница 5: ...ch ITI Model 126070 41mm Visual Adapter to the back of the Eyepiece 3 Remove lens from ITI Model 135630 NVPS Screw NVPS onto the back of the Visual Adapter Remove protective cap from NVPS and attach r...

Страница 6: ...the NVPS relay lens to the ITI Model 135630 NVPS lens will only adapt one way 4 If using a 1 2 format CCD camera just simply screw on the camera For use with 1 3 CCD cameras use the C Mount Extender s...

Страница 7: ...tter Plate by black plastic housing flat side down Slide distal end of plate underneath door 2 Slide or pivot Infrared Emitter Plate around to vary intensity of Infrared light emitted into room 3 To d...

Страница 8: ...age Not Clear Dirt on external optical surfaces Clean optics Scope not focused Focus scope Dirt or liquid on internal optical surfaces Return to ITI for repair 1 3 CCD without C Mount Extender Use C M...

Страница 9: ...exposed wiring It is an excellent conductor REPAIR POLICY If your equipment requires factory attention contact ITI s Customer Service Dept at 413 562 3606 for a Return Authorization Number Please be...