23
Display Function
© 2018 ITEL SNC
<sms "SWAP">
SwapChans=ON
<input close for while TC_SWAP> SwapChans=OFF
<input close for while TC_SWAP> SwapChans=ON
GPIO Enab:<ON/OFF>
:if ON, you can control the exchange of master / backup channels using the
GPIO port.
In OFF mode, the outputs will still be piloted, but the unit will not accept
commands from this interface.
NOTE: The GPIO input must only be enabled if the optional GPIO card has been installed
In: xxx
:Decimal value representing the state of the inputs.
SwapChans:<ON/OFF>
:if ON, the master / backup channels will be exchanged.
The SwapChans function is intended as a temporary mode and will be indicated in the status window with
a warning.
Eth:
if set to 1 enables the Ethernet communication interface if it is installed.
2.5.2
Reading Parameters
The second submenu of the system displays the parameters related to the power supplies and their alarm
conditions
BattV:
battery voltage connected to the rear input. Voltage is considered correct if greater than 20V.
Alm: (ON/OFF)
if it is ON (ON), an alarm will be generated if the battery voltage is less than 18V.
Mains:(OK/NO)
indication of the status of the network power supply.
AlmMin:(1..255/OFF)
timeout in minutes for sending the alarm message for missing network. A message
will be sent after the network is missing for a longer time than the one set, and after the same period of
time, to reboot the network power.
2.5.3
Modem Status and SMS alarms Activation
In the third submenu of the system there are the parameters related to GSM
GSMdBm:
field reading received by the modem. Reading is updated once per second.
SMS:(ON/OFF)
If enabled (ON), enables SMS communication with the device.
IDLE:(IDLE/RECV/SEND/INIT/DEL/BIN)
display of communication activity to PC or modem.
IDLE:
waiting for PC or SMS data from the modem
RECV:
in receiving an SMS message
SEND:
transmission of an SMS message
INIT:
when initializing the modem
DEL:
deleting the received message
BIN:
in binary communication
the numeric value next to the label indicates the secondary code for the current activity.
TestSend:(ON/OFF)
test sending message. When the flag is set to "ON", a test message will be sent to all
Содержание STL-SAT Changeover
Страница 1: ...User s manual STL SAT Changeover 2018 ITEL SNC Author Version Copyright 3 0 0 19 03 2018 A Tomassini...
Страница 2: ......
Страница 5: ...Section 1 Introduction...
Страница 15: ...Section 2 Display Function...
Страница 27: ...Section 3 Control Software...
Страница 49: ...Section 4 GSM SMS Functions...