Configuration Commands
Copyright© Itech Electronic
Co., Ltd.
20
Set the resistance range to exceed 120mΩ.
Query command
RESistance:RANGe?
Arguments
300.00E-3
The present resistance range is 300
m
Ω
.
VOLTage:RANGe <-300 - 300>
VOLTage:RANGe <-1000~1000>
This command is used to set and query the range of voltage.
The command of IT5101/IT5101E model:
VOLTage:RANGe <-300~300>,
The command of IT5101H model: VOLTage:RANGe <-1000~1000>.
Command syntax
VOLTage:RANGe <-300~300>
VOLTage:RANGe <-1000~1000>
Query syntax
VOLTage:RANGe?
Arguments
IT5101/IT5101E:
6.0/60.0000E+0/300.000E+0
IT5101H:
10.0/100.0000E+0/1000.000E+0
Example
VOLTage:RANGe 15
Query command
VOLTage:RANGe?
Arguments
IT5101/IT5101E
:
60.0000E+0
IT5101H
:
100.0000E+0
AUTorange <1|0|ON|OFF>
This command is used to set and query the autorange.
Note
This command is common for the autorange of resistance and voltage. The separate
commands are as follows.