Troubleshooting
The Unit Fails to Turn On
1.
Verify that the
Power Plug
is plugged into an operational wall outlet.
2.
Ensure that the
Power Cord
is fully inserted (leaving less than an 1/8”) to the
Power Adapter
.
3.
Ensure that the
Power Adapter Plug
is fully seated in the receptacle on the back of the unit.
4.
Verify the
Power Button
has been activated on the
Control Panel
.
5.
If the
Power Button
on the
Control Panel
fails, use the
Power Button
on the
Remote Control
. If the
Control Panel
fails, contact your distributor of Inspired TEC (www.inspiredtecllc.com).
The Unit is Operating in High Mode or Away Mode, but No Noticeable Purification is Being Produced
1.
Ensure that the
Purification Plate
is clean (see “
CLEANING: Purification Plate
” page 17).
2.
The
Purification Plate
may not be working because it needs to be replaced. Try installing a new
Purification Plate
.
3.
Check the electrical contact arms which touch the plate to ensure that they are making proper contact with the metal weave on the
Purification Plate
.
4.
Ensure the electrical contact arms which touch the plate are clean. Clean them with a soft cloth and rubbing alcohol.
5.
Turn the lights off in the room and look through the
Front Grille
at the
Purification Plate
. If it is operating properly, it will produce a dim purple glow.
The Purification Plate Generates an Electrical Arc, an Arcing Noise or a Burning Odor
1.
This means the
Purification Plate
is damaged and must be replaced. The unit may or may not display the
Replace Plate LCD
reminder. To order a replacement, contact your distributor or
Inspired TEC (www.inspiredtecllc.com).
The PCO Cell is Not Lighting Up:
1.
Ensure the
PCO Cell Power Connector
is properly seated in the
PCO Cell Power Connector Outlet
(see “
DISASSEMBLY/ASSEMBLY
” pages 15-16).
2.
If the PCO still fails to operate, it needs to be replaced. Contact your distributor or Inspired TEC (www.inspiredtecllc.com).
The Ionization Needle Creates an Electrical Arc:
1.
The
Ionization Needle
needs to be cleaned (see “
CLEANING: Ionization Needle
” page 17). Be sure to complete all of the cleaning procedures (see “
CLEANING
” page 17)
every 30 days of operation.
The Fan Does Not Operate Properly:
1.
Try adjusting the fan speed using the
Control Panel
or
Remote Control
.
2.
Remove the
Front Grille
(see “
DISASSEMBLY/ASSEMBLY
” pages 15-16) to ensure there are no obstructions to the movement of the fan.
3.
If the
Fan
continues to operate improperly or not at all, contact your distributor of Inspired TEC (www.inspiredtecllc.com).
The Unit Makes a Rattling Noise When Taken Out of Packaging
1.
Remove the back panel of the unit (see “
DISASSEMBLY/ASSEMBLY
” pages 15-16). Check to ensure the two brass
Thumb Screws
holding the
Filter Assembly
are in their proper place. If
they are properly installed, remove the
Thumb Screws
and
Filter Assembly
(see “
DISASSEMBLY/ASSEMBLY
” pages 15-16) and check the
PCO Cell
to ensure the two brass
Thumb Screws
securing the
PCO Cell
are installed properly