6.- START UP AND REGULATION
STAND
: Check that the pump is properly installed in its stand.
OIL
: Take off re-filling lid and fill the pump with the provided oil:
SAE 80 W 90 or equivalent.
Check the oil level shown on the oil peep hole
Lubricants list:
CEPSA SAE 80W 90
REPSOL EP 80W/90
SHELL SPIRLAX HD OIL 80W/90
ESSO GEAR OIL 80W/90
AGIP ROTRA MP 80W-90
MOBILUDE HD 80W-90
BP ENERGEAR HT 80W-90
CASTROL HYPOYC
GULF GEAR MP SAE 80W 90
ELF TRANSGEAR HD 80W-90
CHECKING THE HYDRAULIC CIRCUIT
: Check that all valves are
opened and that escapes from priming valves derive the liquid to a
proper receptacle.
CHECKING OF PUMP
: Check visually/auditorilly the proper working
of the pump.
5.5.5- Additional ventilation 115 / 230V
2 7
28
29
30
+2 4
C NO
-
VENTILATION
L N
115 / 230 VAC
2 7
28
29
30
+2 4
C NO
-
VENTILATION
+
-
Factory default 24Vdc
5.5.4- Pulse output isolator
38
39
40
41
27
28
29
31
32
33
34
The pulse output isolator allows to safely
connect any dispositive to an pulse output.
The pulse output is a drycontact. The pulse
output isolator is not necessary when this
output connects with a pulse input of
another Dostec AC.