24
Installation
ENT
ENT
x2
CONFIGURATION
SET UP
IN / OUT
PUMP CALIBRATION
DOSING MODE
5.2.2 Dosing mode
The Dosing Mode function allows the various Advanced Dosing Functions to be selected. These functions
can regulate the speed of the mechanism during the suction and discharge cycle of the pump in order to
optimize the dosing and suit it to the characteristics of the process.
ENT
PUMP CALIBRATION
PROGRESS
Strokes 076
Speed P. 0415
Max.Curr. 04,5
PUMP CALIBRATION
03,333
Dosed volume
l
ENT
CONFIGURATION
SET UP
IN / OUT
PUMP CALIBRATION
DOSING MODE
5.2 CONFIGURATION
5.2.1 Pump calibration
The pump calibration function allows the pump flow to be calibrated in real working conditions via a
product suction test of a given duration. For a correct calibration, a test duration of at least 60 seconds
must be entered. The pump will automatically start during the time of the test.
Once the test is finished, the suction volume must be entered. With this result the equipment will
recalculate the dosing flow.
%
l / h
0 0 0
0 0 0
MODE
25.0
PUMP CALIBRATION
000
Test Time
ST
Dos. Mode
100
Flow
%
PUMP CALIBRATION
060
Test Time
ST
Dos. Mode
100
Flow
%
PUMP CALIBRATION
DVol
0,417 l
l/h
ml
25,0
2,57
100
SVol
FCalib.
Flow
%
l / h
0 0 0
0 0 0
MODE
25.0
Enter the value in the unit
and
validate by pressing
ENT
Press
ENT
to finish the calibration process
Dvol: volume dosed
Flow: flow rate
S.Vol: volume per cycle
F.calib: calibration factor
Reduct: Reducer
Change by pressing
and validate by pressing
ENT