18
Installation
Start/stop the pump
The pump will start if the Remote Activation input is activated.
5.1.2.2 %/ppm Flowmeter
By entering a proportion value (%/ppm) and with a pulse input from a flowmeter, the pump will regulate its
speed to dose the flow according to the desired proportion.
ENT
0001 :
0001
Q = 025
%
M = 005 pulses
PROPORTIONAL X:Y
0001
0001
:
PROPORTIONAL X:Y
Q = 025
%
M =
pulses
005
0001
0001
:
Q =
%
M = 005 pulses
025
PROPORTIONAL X:Y
PROPORT.
%
Set Point
000,05
Stop Pump OFF
PROPORT.
%
Set Point 000,05
Stop Pump
OFF
ENT
ENT
* For the setup of units (%/ppm) see Units in the Configuration section
* For flowmeter setup. See the Configuration section
l / h
60.0
l
%
2 5
3 6
6.25
12
150
l / h
30
m3/h
l
%
6 2
8 9
15.5
Select the number of pump cycles
Change by pressing
and validate by pressing
ENT
Select pump speed in %
Change by pressing
and validate by pressing
ENT
For Y=1 Q must be set at less than 50%
Select the maximum number of pulses in memory
Change by pressing
and validate by pressing
ENT
Proportionality value in % or ppm
Change by pressing
and validate by pressing
ENT
Select OFF to perform proportional dosing with no volume
limit.
Change by pressing
and validate by pressing
ENT
Instantaneous water flow rate
Pressing
ENT
will casue the ON/OFF indicator to toggle to
ON and the pump will start if the Remote Activation input of
is activated