GENERAL INFORMATION
SAFETY DEVICES
• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on
defi ned parameters.
• PRESSURE SWITCH
Positioned in the fume-aspiration area, it is triggered in the
case of a depression in the fumes circuit (e.g. obstructed fl ue)
and interrupts the movement of the pellets.
It blocks pellet loading causing the stove to go out.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It
stops pellet loading, causing the stove to go out.
• AIR FLOW SENSOR
located in the suction channel, it is activated when the
combustion air fl ow is not correct, with consequent pressure
problems in the smoke circuit causing the stove to shut-down.
*
**
SERIAL PORT
The Dealer can install an optional on the AUX outlet for control-
ling the process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear of the stove. This can be
connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032
battery). Its malfunction is indicated with the following messa-
ges (not considered a defect but due to normal wear-and-tear):
“Battery check”. For more detailed information, please contact
the DEALER who performed the fi rst 1st ignition.
FUSE *
Two fuses are inserted in the socket with switch, located on the
back of the stove, one of which operational
*
and the other is
held in reserve
**
.
+
---
•
ELECTRONIC EQUIPMENT
smoke rpm
Lithium
CR2032 ba-
ckup battery
ingnition element
screw
Smoke-expulsion motor
ambient-air sensor
thermocouple
230 vac power
supply
50hz +/-10%
fuse
socket
RS323
fl ow
sensor
forced
ventilation
internal forced-intake
ductwork
internal ducted
ventilation
pressure switch
20-30 Pa