25
ENGLISH
UseR instRUctions
• To confirm the menu, press the
button.
• To return to the previous menu, press the
button for 3 seconds.
• To exit the menu, press the
button for
6 seconds.
sWitcH on/sWitcH off
To switch the boiler stove ON/OFF, press the
button for 3 seconds. The LED above the button will
appear as follows:
-
leD on
boiler stove in operation
-
leD flashing
boiler stove in the process of
switching off or in alarm
-
leD off
boiler stove is switched off
oPeRation
The boiler stove has two operating modes:
- ManUal
In the MANUAL mode, you can set the boiler stove
water temperature operating level, regardless of the
temperature in the room where it is installed.
Based on the temperature of the water, the boiler stove,
independently, regulates the operating power in order
to reach or maintain the set water temperature.
To select the MANUAL operating mode,
press the
button (the LED comes ON) and the
message ‘AIR’ will appear with information about the
temperature.
If you press the
button, you can increase the
temperature for as long as ‘MAN’ appears on the
display (over 40°).
To set the water temperature, press the
button (the
LED comes ON) and the message ‘H2O’ appears.
By using the
button or the
button, you can
adjust the water temperature to reach the temperature
required.
- aUtoMatic
In the AUTOMATIC mode, you can set the water
temperature and the required temperature for the
room where the boiler stove is installed.
When the required room temperature (AIR) or water
temperature (H2O) is reached, the boiler stove will
automatically enter modulation mode with minimum
power level.
To set the room (AIR) temperature, press
(the LED
will come ON), the current operating temperature
will be displayed. By using the
button or the
button, you can adjust the temperature to reach the
temperature required. The temperature is measured
by the probe behind the boiler stove.
fan aDJUstMent
It is possible
• to set AUTO mode. This mode automatically
regulates the fan speed based on stove power;
• manually set the fan speed based on the quantity
of warm air or desired sound level;
• deactivate the fan by setting it to OFF (stove
power will automatically be limited).
To access the setting press
for 2 seconds (the
display will show “M1 Set Clock”.
Then press
until the display shows “M3 Adjust fan
1”.
To confirm, press the
button.
Use buttons
and
. to set the fan speed or set
the mode to AUTO or OFF.
loaD scReW feeDeR (only if the boiler
stove has completely run out of pellets)
To load the screw feeder, you must enter the MENU;
press the
button for 2 seconds. Press the
button until the message “M7 first load” appears on
the display.
Press the
button to confirm and then press the
button to activate the function.
This operation can only be performed with the boiler
stove OFF and completely cold.
Note: during this phase the smoke extractor will remain
ON.