![Italiana Camini Dida Idro Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/italiana-camini/dida-idro/dida-idro_installation-use-and-maintenance-manual_2094750025.webp)
25
ENGLISH
tRoUblesHooting
®
Message
PRobleM
solUtion
al07
Shut-down due to exceeding
maximum fumes temperature.
•
Check the type of pellet (contact the technician if in
doubt)
•
contact the technician
al08
Shutdown due to overheated
water
•
check the system has been vented
•
contact the technician
al09
displays when the combustion
air intake is below the set level
•
Ensure the furnace door is closed
•
Check that the stove, exhaust and combustion air
duct are clean.
al c
Intervenes if there are electrical
absorption problems on the
gearmotor
•
Contact the technician
al H
Intervenes if there are electrical
absorption problems on the
gearmotor
•
Contact the technician
Messages WHicH Do not sHUt tHe stoVe DoWn, bUt aRe siMPly WaRnings
Message
PRobleM
solUtion
“Bat.
1”
The boiler stove does not stop
operating, although the term is
displayed.
• The back-up battery on the board needs replacing.
if pellet loading fails to occur,
especially after a power failure, check whether the safety thermostat has
intervened.
If the temperature is too high, it switches off the product by cutting off the power supply to the gearmotor.
If the thermostat has intervened, it must be reset via the reset button at the back of the boiler stove after removing
the protective cap.
Содержание Dida Idro
Страница 1: ...EN Installation use and maintenance page 2 Dida Idro Pellet boiler stove...
Страница 26: ......
Страница 27: ......
Страница 28: ...code 941344 GB 03 17 A 941344 GB...