background image

 
 

 Contents 
 

 Introduction ................................................................................................................................. 1

 

 Package content .......................................................................................................................... 3

 

 Specifications ............................................................................................................................... 4

 

 Operation..................................................................................................................................... 5

 

Device overview ....................................................................................................................... 5

 

Device description ................................................................................................................... 5

 

Recommended Target Debug Connectors and Position .......................................................... 6

 

Operating the Active Probe at 160 MHz DAP clock ................................................................. 8

 

winIDEA

TM

 settings .................................................................................................................. 9

 

Hardware selection ............................................................................................................. 9

 

Debug interface voltage levels ............................................................................................ 9

 

DAP Clock .......................................................................................................................... 10

 

 Accessories ................................................................................................................................ 12

 

IOM6 product line .................................................................................................................. 12

 

Infineon DAP Active Probe Accessories ................................................................................. 12

 

 

Содержание Infineon

Страница 1: ...Infineon DAP Active Probe V1 4 User Manual ...

Страница 2: ...ts are reserved Duplication of these documents is allowed for personal use For every other case a written consent from iSYSTEM is required Copyright iSYSTEM AG All rights reserved All trademarks are property of their respective owners iSYSTEM is ISO 9001 certified company www isystem com ...

Страница 3: ...5 Device description 5 Recommended Target Debug Connectors and Position 6 Operating the Active Probe at 160 MHz DAP clock 8 winIDEATM settings 9 Hardware selection 9 Debug interface voltage levels 9 DAP Clock 10 Accessories 12 IOM6 product line 12 Infineon DAP Active Probe Accessories 12 ...

Страница 4: ...ing and code coverage of the application via the trace interface as well as combine data captured by the IOM6 accessories Various third parties also provide software tools to perform advanced worst time execution analysis based upon the data winIDEA can export When a Real Time Operating System RTOS is in use the state of the RTOS and its task can also be visualized testIDEA The testIDEA environmen...

Страница 5: ...s is to avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Please ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage surges e g caused by thunderstorm mains power Do not operate without cover Do not operate the device with cover removed Avoid circuit and wire exposure Do not to...

Страница 6: ...r ordering code IC57163 is delivered with the following components InfineonDAP ActiveProbe Set of two 10 pin 1 27mm 10 cm long ribbon cables 1m FNET Micro Cable Ordering code IC57163 Ordering code IA10PIN10PIN127 AP Ordering code BB FNETMICRO 100 User manual ...

Страница 7: ...5 kg OPERATION Communication interface to Blue Box iSYSTEM proprietary FNET Debug signal valid input voltage range 3 3V CMOS TTL Power consumption 1 5W depends on operation mode PROTECTION Debug signals 15Ω series termination protection resistors ESD protection devices DAP1 3 and DAPE1 3 10kΩ pull down DAP_RESET 1kΩ pull up 33Ω series termination protection resistor VREF 1kΩ input impedance ...

Страница 8: ...l 3rd Data Pin IN OUT Ground GND 9 10 RESET Target Reset Pin OUT Signal direction definition OUT output from the Active Probe to the target microcontroller IN input to the Active Probe from the target microcontroller B 10 pin DAPE connector with the following pinout Signal Direction Signal Description Signal Pin Pin Signal Signal description Signal Direction IN Reference Voltage VREF 1 2 DAP1 DAP ...

Страница 9: ...se only original iSYSTEM accessories for powering and connecting with the iC5700 Consult with iSYSTEM before attempting to use any other accessory Recommended Target Debug Connectors and Position It is recommended to use target debug connector s with the keying shroud option since wrong connection can damage the hardware When connecting the Active Probe to the target through a single debug interfa...

Страница 10: ... Active Probe to the iC5700 FNET Port trough the FNET Micro Cable delivered along the Active Probe If longer cable than 1m is required for example when debugging ECU in a car with a very limited space optional 3 m and 5 m FNET Micro cables are available from iSYSTEM Although it looks similar to the HDMI interface the FNET Port is not compatible with HDMI or any HDMI accessories Connecting iSYSTEM ...

Страница 11: ...ctive Probe in conjunction with the DAP clock exceeding 100 MHz connection to the target microcontroller is critical Have in mind that the period is only 6 25 ns at 160 MHz clock which is maximum DAP frequency Maximum signal integrity has to be ensured between the Active Probe and the DAP DAPE port of the target microcontroller For the DAP operation at frequencies higher than 100 MHz the following...

Страница 12: ...rted limited maximum DAP frequency DAPE debug port not supported or through the Infineon DAP Active Probe DAP and DAPE debug interface supported including max DAP DAPE frequency connecting to the iC5700 FNET port Associated debug hardware is selected in the Hardware Emulation Options Probe tab Select Active Probe when using the Infineon DAP Active Probe Debug interface voltage levels Debug interfa...

Страница 13: ...neous DAP and DAPE interface operation DAP interface is used per default DAP 2 pin DAP with single data line or DAP2 3 pin DAP2 with two data lines operation mode can be selected and DAP frequency set When setting freqeuncy do not exceed the maximum DAP frequency of the target microcontroller which also depends on the microcontroller configuration Double check that the DAPE check box is unchecked ...

Страница 14: ...11 Other more general Tricore related settings are described within winIDEA on lin help ...

Страница 15: ... add on module IC57041 Analog digital add on module IC57163 Active probe with DAP2 interface IC57125 Active probe with HSSTP interface Infineon DAP Active Probe Accessories Ordering Code Description IA10PIN10PIN127 AP Set of two 10 pin 1 27mm 10 cm long DAP interface ribbon cables BB FNETMICRO 100 1 m FNET Micro Cable Active Probe BB FNETMICRO 300 3 m FNET Micro Cable Active Probe BB FNETMICRO 500...

Страница 16: ...to ensure the accuracy and reliability of the information provided in this document at the time of publishing While iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...

Отзывы: