SGZB11C would be in active status for 2 minutes for communication.
5-7. Battery
SGZB11C will send a low-power report to the ZigBee network when the operating voltage is lower than
3.2V by default.
The related data:
Power configuration cluster (ID:0x0001)
Battery voltage attribute (ID:0x0020)
The reporting voltage can be adjusted. There are 4 voltages for choosing: 3.5V/ 3.4V/ 3.3V/
3.2V. It is recommended that the minimal reporting internal is longer than 3-minute.
5-8. Infrared Sensor Detection and Report
When infrared sensor detects a movement, SGZB11C1 will send the report to the CIE device and go to
Occupied status. The indicator will flash
red
once. In Occupied condition, SGZB11C1 will detect the
further movement after 84 seconds (120 * 70%) by default. Until no additional movement is detected
within the period of 120 seconds, SGZB11C1 will go to Unoccupied condition and send the report to
ZigBee network.
After SGZB11C1 joins the ZigBee network, the infrared sensor will not be active within 1 minute.
Under the circumstances SGZB11C1 is not in a ZigBee network, it will start to join a network after
the SGZB11C1 detects a movement.
Users could change the detecting sensitivity by adjusting the Sensor Sensitivity
Adjuster. Clockwise adjustment → Higher sensitivity
This device supports “Voltage status” and “Occupancy status” report.
For “Voltage status” report:
(1)
If ZB11D does not bind any device (
ClusterId: 0001
), it will not send report.
(2)
After binding, ZB11D will send voltage status to bind device.
Default configuration:
Min: 3600s, Max: 3600s, Report change:1
For “Occupancy status” report:
(1)
If ZB11D does not bind any device (
ClusterId: 0406
), it will not send report.
(2)
After binding, ZB11D will send voltage status to bind device.
Default configuration:
Min: 0s, Max: 3600s, Report change:0
Note: it is recommended to set MinInterval as small as possible such like “0” for immediately
detection and avoid missing IR detection report.
5-9. Movement Detection and On/Off Control
When infrared sensor detects the movement and the surrounding light intensity is low, it sends a light-on
message. In this condition, SGZB11C will detect the further movement after 84 seconds (120 * 70%) by
default.