background image

3

Seebacher GmbH 

www.seebacher.de 

Phone: +49 (0) 80 41 / 77 77 6

Marktstrasse 57, 83646 Bad Tölz 

[email protected] 

Fax: +49 (0) 80 41 / 77 77 2

The  module  is  designed  for  mounting  in  a  flush-mounted  box 
according  to  DIN  49073.  Extreme  environmental  conditions 
impair the function of the product.

• 

Protect module from shocks

• 

Use module indoors only

• 

Protect module from humidity

In addition to these safety instructions, you must also observe 
the special safety instructions listed in the individual chapters for 
the individual acts.

2.4. Qualification of staff

Assembly, commissioning, operation, maintenance, decommis-
sioning and disposal may only be carried out by qualified staff. 
Work  on  electrical  parts  may  only  be  carried  out  by  a  trained 
electrician  in  accordance  with  the  applicable  regulations  and 
directives. Other activities in connection with the ISYGLT module, 
such as assembly and installation of system components with 
tested standard plug connections, as well as operation and con-
figuration of the ISYGLT module may only be carried out by trai-
ned staff.

2.5. Changes to the product 

Unauthorized modifications to the ISYGLT module which are not 
described in this or the other applicable instructions can lead to 
malfunctions and are prohibited for safety reasons.

2.6. Use of spare parts and additional equipment

The module may be damaged if unsuitable spare parts and addi-
tional  equipment  are  used.  Only  use  original  spare  parts  and 
additional equipment from the manufacturer.

2.7. Liability notes

SEEBACHER  accepts  no  liability  or  warranty  whatsoever  for 
damage and consequential damage caused by non-compliance 
with  the  technical  regulations,  instructions  and  recommendati-
ons. SEEBACHER shall not be liable for any costs or damage 
incurred by the user or third parties as a result of the use of this 
equipment, in particular improper use of the equipment, misuse 
or malfunction of the connection, malfunction of the equipment 
or connected devices. 

SEEBACHER accepts no liability for printing errors.

2. Safety instructions

Observe  the  following  general  safety  instructions  when  installing 
and commissioning the device:

Assembly and installation of the ISYGLT module may only be carried 
out by a qualified electrician. Other activities in connection with the 
ISYGLT module, such as assembly and installation of system com-
ponents with tested standard plug connections, as well as operation 
and configuration of the ISYGLT module may only be carried out by 
trained staff.

Observe the electrical installation regulations of the country in which 
the device is installed and operated as well as its national accident 
prevention regulations. In addition, observe internal company regu-
lations (work, operating and safety regulations).

Before working on the ISYGLT module system, it must be 
disconnected  from  the  power  supply  and  secured  against 
being switched on again. After completion of the assembly, 
installation and maintenance work, an electrical check must 
be carried out! Check all protective conductor connections 
and the voltages at all connection plugs as well as at each 
individual module slot.

2.1. Intended usage 

The module is only suitable as a BUS coupler for the input and 
output  of  commands  and  signals  in  conjunction  with  ISYGLT 
system  components.  Any  other  use  is  not  intended.  The  limit 
values stated in the technical data must not be exceeded under 
any circumstances. This applies in particular to the permissible 
ambient  temperature  range  and  the  permissible  IP  protection 
type. For applications with a higher required IP protection type, 
the ISYGLT module must be installed in a housing or a cabinet 
with a higher IP protection type.

2.2. Predictable mishandling

The module must not be used in the following cases in particular: 

 explosive area 

When operating in explosive areas, sparking can lead to defla-
gration, fire or explosions.

2.3. Safe handling

This module corresponds to the state of the art and the recog-
nised safety regulations. Each device is tested for function and 
safety before delivery.

Only operate this module in perfect condition in accordance with 
the operating instructions, the applicable regulations and directi-
ves of the country in which the device is installed and operated, 
and the applicable safety and accident prevention regulations.

Содержание IN-04U

Страница 1: ...GmbH www seebacher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 IN 04U Article no 80024040 Flush mountedTransmitter Module Technical Data Instruc...

Страница 2: ...e handed over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the m...

Страница 3: ...following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may only be carried out by a qualified electrician Other activities i...

Страница 4: ...ng screws Assembly site The product can be installed in any position in a casing to be deter mined by the electrician box lamp switch cabinet Observe maxi mum ambient temperature Assembly steps Read c...

Страница 5: ...ed by means of wires Inputs Outputs 4 optocoupler inputs Function displays 1 red LED indicates the operating voltage 1 flashing yellow LED indicates the communication with the master via the subnet Co...

Страница 6: ...net RS 485 max 5 6V limited by Z diodes Dimensions DxH 50x18mm Weight approx 90g Connection screw terminals 2 5mm for BUS solid wires 0 8mm for inputs Operating temperature 10 C to 50 C Storage temper...

Страница 7: ...7 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 11 Wiring diagram 24V 0V BUS A BUS B E1 E2 E3 E4 COM A 2 3 4 5 6 7 8 1 Art no 80024040 ISYGLT IN 04U Address wh bn gn ye...