1. Notes on documentation

These  instructions  are  intended  for  qualified  personnel  who  are 
familiar with the assembly, installation and operation of the ISYGLT 
system.  It  is  essential  that  you  read  these  operating  instructions 
through before commissioning and keep them accessible for further 
use.
SEEBACHER cannot accept any liability for damage or malfunctions 
resulting from failure to observe these instructions.

1.1. Retention of documents

These instructions and all other applicable documents are part 
of the product. They must be handed over to the device operator. 
The operator will store the documents so that they can be made 
available if necessary.

1.2. Symbols used

Observe the following safety and other instructions in the manual:

  Handling instruction

The hand indicates that you should carry out an act.

  Danger!

Immediate danger to life!

  Attention!

General notes, useful information and special features

Directory of Content

1. Notes on documentation

1.1. Retention of documents

1.2. Symbols used

2. Safety instructions

2.1. Intended usage

2.2. Predictable mishandling

2.3. Safe handling

2.4. Qualification of staff

2.5. Changes to the product

2.6. Use of spare parts and additional equipment

2.7. Liability notes

3. Warranty

4. Declaration of Conformity

5. Service address

6. Maintenance / Care / Disposal

7. Storage

8. Assembly

9. Product description

10. Technical Data

10.1. Pin assignment

11. Wiring diagram

Содержание IN-04U

Страница 1: ...GmbH www seebacher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 IN 04U Article no 80024040 Flush mountedTransmitter Module Technical Data Instruc...

Страница 2: ...e handed over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the m...

Страница 3: ...following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may only be carried out by a qualified electrician Other activities i...

Страница 4: ...ng screws Assembly site The product can be installed in any position in a casing to be deter mined by the electrician box lamp switch cabinet Observe maxi mum ambient temperature Assembly steps Read c...

Страница 5: ...ed by means of wires Inputs Outputs 4 optocoupler inputs Function displays 1 red LED indicates the operating voltage 1 flashing yellow LED indicates the communication with the master via the subnet Co...

Страница 6: ...net RS 485 max 5 6V limited by Z diodes Dimensions DxH 50x18mm Weight approx 90g Connection screw terminals 2 5mm for BUS solid wires 0 8mm for inputs Operating temperature 10 C to 50 C Storage temper...

Страница 7: ...7 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 11 Wiring diagram 24V 0V BUS A BUS B E1 E2 E3 E4 COM A 2 3 4 5 6 7 8 1 Art no 80024040 ISYGLT IN 04U Address wh bn gn ye...

Отзывы: