background image

 

 

Ground Connecting 

The switch must be properly grounded for optimum 
system performance. 

5-Port series 

5-Port with 
PoE series 

8-Port series 

 

 

 

 

Ethernet Interface Connecting (RJ45 
Ethernet) 

The switches provide two types of electrical (RJ45) 
and optical (mini-GBIC) interfaces. 

Connecting the Ethernet interface via RJ45: 

 

To connect to a PC, use a straight-through or a 
cross-over Ethernet cable, 

 

To connect the switch to an Ethernet device, use 
UTP (Unshielded Twisted Pair) or STP (Shielded 
Twisted Pair) Ethernet cables. 

 
The pin assignment of RJ-45 connector is shown in 

the following figure and table. 

 

 

 

Pin 

Assignment 

PoE 

Assignment 

1,2 

T/Rx+,T/Rx- 

Positive V

Port

 

3,6 

T/Rx+,T/Rx- 

Negative V

Port

 

4,5 

T/Rx+,T/Rx- 

7,8 

T/Rx+,T/Rx- 

Ethernet Interface Connecting the (Fiber, 
SFP) 

For a 100 Mbps fiber port available, please prepare 
the LC connectors or SC connectors (with the use of 
an optional SC-to-LC adapter). They are also 
available with multimode, single mode, long-haul (for 
connections up to 120+ km) or special-application 
transceivers.   

For a 1000 Mbps fiber port available, please use the 
mini-GBIC SFP (small form pluggable). These 
accept plug in fiber transceivers that typically have 
an LC style connector. They are available with 
multimode, single mode, long-haul (for connections 
up to 80+ km) or special-application transceivers. 

For each fiber port there is a transmit (TX) and 
receive (RX) signal. Please make sure that the 
transmit (TX) port of the switch connects to the 
receive (RX) port of the other device, and the receive 
(RX) port of the switch connects to the transmit (TX) 
port of the other device when making your fiber optic 
connections. 

DANGER: 

Never attempt to view optical connectors 
that might be emitting laser energy. 

 

Do not power up the laser product without 
connecting the laser to the optical fiber and 
putting the cover in position, as laser 
outputs will emit infrared laser light at this 
point. 

Power Connecting 

The switch can be powered from two power supply 
(input range 12V 

– 58V). Insert the positive and 

negative wires into V+ and V- contact on the terminal 
block and tighten the wire-clamp screws to prevent 
the wires from being loosened. 

 

Note:  1.

 

The DC power should be connected to a 
well-fused power supply. 

 

2.

 

Input power should be within the range of 
54~58VDC for PoE+ compliant, or 48-58VDC 
for PoE compliant.

 

 
 

Alarm Relay Connecting 

(for Non-PoE Models)

 

The alarm relay output contacts are in the middle of 
the DC terminal block connector as shown n the 
figure below. 

By inserting the wires and set the DIP switch of the 
respective Port Alarm to 

“ON”, the relay output alarm 

will detect any port failures, and form a short circuit. 

The alarm repay out is 

“Normal Open”. 

 

Alarm

system

Extra power

system

Maximum 1A  / DC 24V

 

Alarm

system

Extra power

system

Maximum 1A  / DC 24V

 