background image

7

© Island Pellet Stoves 2016

Lundy 5kW Operation Manual - 19.02.16

C ONTROLLING ROOM TEMPERATURE

With the Island controller you have two options for setting the room temperature. You can:

a) Use weekly timer programs
b) Set or modify the room temperature manually

Using the weekly timer programs you can fully automate the operation of your combustion system and 

little or no user intervention is required. You can also set or modify the room temperature manually. 

If you are using the weekly timer programs, this enables you to temporarily override the program 

settings.

The program settings are reset when conditions, set with the timer, are met (for example, end time 

is reached and the combustion system turns off). To view the current room temperature, tap on the 

down arrow to enter the Temperature context menu. The current room temperature value is shown 

on the display.

To set the desired room temperature, in the Temperature context menu tap  on the plus or minus 

icons to increase or decrease the temperature. The changes will be saved automatically and the 

display will then show the current room temperature.

SHUT DOWN

Select  OFF  in  the  top  left  corner  of  the  display.  If  you  were  in  the  edit  mode,  the  changes  are 

discarded and the edit mode is exited. The Stove power will remain on and safety features will run if 

initiated by abnormal conditions (e.g. overheat).

ROUTINE MAINTENANC E

Cleaning is essential to maintain the efficiency and reliability of the stove and is the user’s responsibility. 

DAILY

Clean the sliding grate; The sliding grate is located below the stove opening and can be pulled out 

by a handle as shown below. To clean it, withdraw the grate, and then reinsert it correctly with the 

handle pointing down. This is required to be done daily, best done late in the evening after the stove 

has shutdown, so that the grate is clean for duty the next morning.

Please Note: 

The door handle should only be opened when the unit is not operating and is at room 

temperature.

WEEKLY

Removing ash; The ash accumulates in the area underneath the sliding grate and should be removed 

once for every 100kg of fuel used (for example once for every 10 bags of fuel if each bag weighs 

10kg). It is recommended that this is done using a vacuum cleaner designed for ash.

Please Note:

 The ash should be vacuumed out only when the unit is not operating and is at room 

temperature.

Door Glass - The glass will self clean is there is sufficient heat generated from the stove. However, 

if there is a build up of debris on the glass it may be due to draft conditions, poor quality fuel or very 

low burning for a long time. To clean the glass, it is recommended to use a soft dry cloth. Do not use 

a detergent or liquid which could penetrate any cracks, thereby making them more visible.

Содержание LUNDY5

Страница 1: ...1 Island Pellet Stoves 2016 Lundy 5kW Operation Manual 19 02 16 Basic Operation Manual Lundy 5kW Pellet Stove LUNDY5...

Страница 2: ...ust be accessible after installation This appliance must not be used to burn coal waste or fuel not recommended by the manufacturer Do not use any inflammable liquids for ignition During the filling p...

Страница 3: ...ration and menus The infra red sensor is used for remote control unit The display shows the set or current values for the currently selected menu option With on screen buttons you can navigate through...

Страница 4: ...in menu Close the menu Increase Navigate back Decrease Previous sub menu page Enter timers menu Next sub menu page Enter statistics menu Info about the selected submenu Enter settings menu Fuel autono...

Страница 5: ...ys will be highlighted Set the timer start hours and minutes for the first time interval by tapping on Time start and then and or icons Save the settings by tapping OK Set the timer finish hours and m...

Страница 6: ...nutes before entering a Burning phase Once in the Burning phase the Stove continuously checks conditions such as air and flue temperatures If needed it will restart by itself It will continue burning...

Страница 7: ...main on and safety features will run if initiated by abnormal conditions e g overheat ROUTINE MAINTENANCE Cleaning isessentialtomaintain theefficiency andreliability of thestoveand istheuser sresponsi...

Страница 8: ...dance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for eit...

Страница 9: ...ions are locked including turning the stove ON OFF Red icon will be displayed on the idle and main menu screens Please Note We recommend you use the screen lock option if children are able to access t...

Страница 10: ...ce to order replacement CR2032 recommended A005 Speed sensor Call out service personnel A006 Door opened Ensure door is closed properly A007 Pressure airflow sensor Call out service personnel E002 IR...

Страница 11: ...et fuel is used 6mm diameter EN Plus A1 Installation only by a party authorised by Island Pellet Stoves Ltd Annual maintenance of stove and flue only by a party authorised by Island Pellet Stoves Ltd...

Страница 12: ......

Страница 13: ...ere it is clear that the parts were faulty when you received them we will send replacements or repair the item free of charge as soon as possible This is in addition to the manufacturer s guarantee wa...

Страница 14: ...oves Limited All the Intellectual Property in our designs belongs to Island Pellet Stoves Ltd Any infringements will be pursued vigorously Island Stoves reserves the right to vary features and data sh...

Отзывы: