Enclosure Dimensions:  

 

Control Panel - Stainless Steel 16 gauge           

Wall Box – 16 gauge powder coated sheet metal   

 

 9.875 X 16 

 

 

 

             6.0 X 12.25 X 4.0 

 

      * All dimensions are in inches 


 
 
 

 

 

 

 

 

 

Содержание FGS-3X13

Страница 1: ...tion range for the sensor is 1 25 LEL Lower Explosion Limit or 50 10 000 ppm ISIMET Gas Sensor Independent Unit Installation Operations Start up and Maintenance Instructions Table of Contents Page Warranty 2 Enclosure Dimensions and Model Number Description 3 Mounting Instructions Flush 4 Mounting Instructions Surface Mount 4 Mounting the Wall Panel 4 Circuit Output Configurations 5 Adjusting the ...

Страница 2: ...hts shall be limited to the total sum of the amounts paid for the product by the purchaser Limits of Liability ISIMET s liability shall be limited to costs of repair or replacement parts The Gas Sensor Panel is not intended for usage other than those expressly described in this manual ISIMET shall not be liable for damage or injury caused by the improper use of the product ISIMET does not warrant ...

Страница 3: ...3 Enclosure Dimensions Control Panel Stainless Steel 16 gauge Wall Box 16 gauge powder coated sheet metal 9 875 X 16 6 0 X 12 25 X 4 0 All dimensions are in inches ...

Страница 4: ...urface mount the unit the provided mounting hardware must be used Care should be taken to not damage the unit when mounting and to verify that the mounting means securely fastens the unit to the wall surface A stainless skirt is provided in order to conceal the wall box from view An arrow on the inside of the skirt indicates mounting direction Mounting Flange Wall Housing Mounting the Wall Panel V...

Страница 5: ...30 sec Delay Care should be taken to not change the delay setting to a non desired period ISIMET FGS Gas Sensor 3000 Series Short Circuit Rating 1 kA Gas Sensor Plug Input LED Plug Input Lamp Plug Input Reset Switch Input Header Plug Caution Header and Plug are Polarized Improper installation may cause Sensor Malfunction JP5 Reset Lamp Bi Color LED Sensor 120 VAC White Black Fuse Schedule Fuse 1 1...

Страница 6: ... conduits are located at the top left and right of the Wall Box Connect rigid conduit for the required 120 vac electrical service to the upper left top of the enclosure at the junction box Connect conduit for the output power to the upper right top of the enclosure Wiring the Unit Important Verify that the electrical supply is disconnected prior to connecting wiring to the Gas Sensor To wire the C...

Страница 7: ...ure is factory pre set based on customer ordering stipulations Settings other than 0 will allow a brief period between detection and notification so that the gas outlet that is the cause of the detection can be turned OFF before the unit transmits a shut down signal During this period the panel mounted lamp will flash notifying the user that raw fuel gas has been detected Once the time delay elaps...

Страница 8: ...8 ISIMET MAPA LLC 103 W CJ Wise Parkway PO Box 129 Naples TX 75568 903 897 0737 Fax 903 897 0740 www ISIMET com Innovative Systems Integrating Mechanical and Electrical Technology ...

Отзывы: