[Error content]
Scale (P-930) memory settings are abnormal.
[Detail]
Scale settings and console settings are different.
[Solution]
[OK] button
[Remarks]
Need to re-set span.
[Cause]
Scale (P-930) memory settings are abnormal.
[Response]
1. Perform spring span.
2. If the same error occurs, replace board P-930.
1
600
Ishida WM-4000 Error Codes and Solutions (600-2099)
March 2015
65/84
Содержание WM-4000
Страница 1: ...WM 4000 AUTOMATIC WRAPPER Error Codes and Solutions 600 2099 March 2015 ...
Страница 3: ...0601 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 2 84 ...
Страница 5: ...0602 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 4 84 ...
Страница 19: ...0615 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 18 84 ...
Страница 28: ...0650 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 27 84 ...
Страница 53: ...1502 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 52 84 ...
Страница 61: ...Page 1 of 1 1520 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 60 84 ...