[Error content]
Applicator standby position is abnormal
[Detail]
The front/rear applicator standby position sensor (Y direction sensor
(front)) was not switched off when applicator operation began.
[Solution]
[RETURN] button, [PLU] key
[Remarks]
If this sensor is blocked from light, the applicator is in the forward
position and is receiving an okay signal for operation.
[Cause]
The applicator attempted to start operation without the applicator in
the forward position.
[Response]
1. Check the Y-direction sensor (front) (B56) operation.
2. Bring the applicator to the forward position so the detection
board switches off.