[Error content]
There was no response from the tray detector (P-915)
[Detail]
・Unable to communicate between the console (P-910) and the tray
detector
・The communication phase number is in the sub-error.
・Errors after power ON process completion result in this error.
[Solution]
[OK]
-> Cut communication with the detector. Operate without the
detector.
[RETRY]
-> Check connection with the detector. If connection can be
confirmed, the error is cleared.
[Remarks]
[Cause]
There was no response from the tray detector (P-915).
[Response]
Press the [RETRY] key to re-attempt communication.
Consider the following causes if the same error occurs:
1)Connector is unplugged
2)Shorted harness
3)Board P-915 malfunction
4)Board P-918 malfunction
5)Platform P-910 malfunction
• The problem may also occur if there is a closed-circuit failure in
the P-916 and P-920 RS-485 line. Check this if the problem is
not solved by 1 through 5.
• Connect boards P-915, P-916, and P-920 one at a time to
search for the board closed-circuit failure.
1502
Ishida WM-4000 Error Codes and Solutions (600-2099)
March 2015
51/84
Содержание WM-4000
Страница 1: ...WM 4000 AUTOMATIC WRAPPER Error Codes and Solutions 600 2099 March 2015 ...
Страница 3: ...0601 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 2 84 ...
Страница 5: ...0602 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 4 84 ...
Страница 19: ...0615 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 18 84 ...
Страница 28: ...0650 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 27 84 ...
Страница 53: ...1502 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 52 84 ...
Страница 61: ...Page 1 of 1 1520 Ishida WM 4000 Error Codes and Solutions 600 2099 March 2015 60 84 ...