20 - 22
Leaking Error
installation
To avoid any leaking during
running service time, it should be
observed up to 1mm distance between
the tube end to the double sleeve.
No discharging
to the lube
point.
Air in the centralized
lubrication system
Vent centralized lubrication system.
Pipe blocked or broke
Disconnected the pipe from the output
adapter to visual check if discharging
from the lubrication unit. If so, the
lubrication functions. Check where it
blocked or broke in the delivery pipe
and repair.
Gear pump or motor jammed
Clean the reservoir and return the
lubrication unit to iSHAN or iSHAN
agents for repair.
No pressure build-in
Check pressure switch. Replace it if
failure. If not, refer to the
troubleshooting instruction.
Electric leakage
If the water comes in contact
with electric wire or earth faults
in electrical appliances.
Indicate with remark where occurred
and then return to iSHAN for repair.
6 Warranty
iSHAN warrants that it will repair or replace any product manufactured and sold by it
which proves to be defective in material or workmanship within a period of one year from the
date of original purchase for the clients. Any warranty claim will be considered invalid if the
product is not complete or it was disassembled or failure to manual or damage caused by act of
God. Any return must consult with iSHAN and obtain iSHAN’s approval before action.
7 Announcement
Warning
:
iSHAN reserves the right to make content and technical changes without
notice and it includes the manual. It is invalid to file a lawsuit against iSHAN in above
changes.