background image

 

 

 

45 

 

 

 

x1R Standard

 

If x1R Smart is set in 

Standard

 version, there is an additional menu, not visible if 

Single Action

, that 

allows to set 2 important options:   

 

Outside Knob:

 following an opening command the lock withdraws bolts and latch to open 

the door. This is set as default from the factory. 

 

Outside Handle

: following an opening command, the lock withdraws the bolts but not the 

latch. Lower the outside handle to manually withdraw the latch to fully open the door.  

 

         

 

 

           

 

 

 

 

 

 

Advanced

 

 

Change from 

Outside 

Knob 

to 

Outside 

Handle

 and viceversa 

 

Outside  Knob

  and 

Outside  Handle

  respectively  corresponds  to  the  previous  Argo 

Functional Modes 1 

and

 2

 

 

 

Содержание X1R Smart

Страница 1: ...1 x1R Smart User Manual Argo 2 3 ...

Страница 2: ...2 ...

Страница 3: ...keep it handy It will come useful again whenever you want to reprogram or check your lock as well as for doing ordinary maintenance and solving any problems For commercial documents technical documents and certifications refer to the ISEO Zero1 website at the following link http gamma iseozero1 com en controllo accessi Information icons For an easy reading of the manual take note of the following ...

Страница 4: ...use this manual About This Manual In the Table of Contents click on the argument or page number to directly go to the related paragraph or chapter Go back to Table of Contents clicking on the chapter small title ...

Страница 5: ...evice Access control device electronic and or mechanical device that allows selective access through a door Actuator device that act an opening or closing action following an external control signal i e a remote opening command Argo app it is an app for smartphones Bluetooth Smart ready that allows to manage and program the Access control device Cable gland spring it is a concealed lead cover inst...

Страница 6: ...ned for any user who wishes to gain access without the use of authorized credentials Hidden External Reader it s a Bluetooth and RFID reader like the External control module with no PIN option that can be fit inside the door in order to have from the outside a clean door surface solution called in jargon clean facade door so that from outside nothing is visible Internal control module it is an acc...

Страница 7: ...tion x1R Smart version featuring an advanced and precise mechanical system that allows the internal handle to retract latch and deadbolts in one unique and smooth movement also called anti panic function Smart series Access control device which embeds a Bluetooth radio module to communicate to the compatible smartphones by the Argo app Standard x1R Smart version without the Single Action functiona...

Страница 8: ...ew 16 What is x1R Smart 16 System components 17 Technical data 18 Dimensions 19 Options and versions 20 Electrical connections standard 24 Example of 8 poles Multifunction Cable wiring scheme 26 Getting Started 27 Package contents 27 Product identification 27 Product codification 28 Installing x1R Smart 29 First switch on 29 Device Initialization 29 Add credentials without Argo App 31 Add a PIN co...

Страница 9: ...sensor contact 52 x1R Smart as actuator 54 More advanced function about Argo app 57 Maintenance 58 Battery replacement 58 Notes on battery usage by x1R Smart 60 Cleaning 61 Appendix 62 Events log messages 62 Light and acoustic signal 64 Wiring specifications 65 Why some Functional Modes are no more present on Argo 66 Troubleshooting 67 Argo app error messages 67 x1R Smart troubleshooting 67 Techni...

Страница 10: ...gerous Do not work on the door with the lock installed in order to prevent wood or metal residue getting into the lock Distance between striking plate and latch tip completely in from both motor or key must be between 2 and 3mm Handle must not have any friction during the return phase Connecting rods must have a play of at least 1 millimeters so that the deadbolt does not remain subjected to tract...

Страница 11: ... for any damage resulting from improper erroneous or unreasonable use In case of failure and or malfunction of the device switch off the power supply An authorized technical support center must be contacted in order to repair the device Failure to comply with the above statement may compromise the safety of the device Do not expose the device to dripping or splashing water Single Action version al...

Страница 12: ...the motor to rotate in neutral Make sure that External control module is not subject to heavy rain If the door is installed with the x1R Smart battery holder placed in the top side of the door make sure there is enough space from the ceiling to remove battery holder in case of battery replacement needs Safety and Environment WARNINGS Battery holder ...

Страница 13: ... standard EN 14846 2008 With classification 3X9E0P713 And with the standard only Single Action version EN 179 2008 With classification 377B1452AB DoP Declaration of conformity available on the web site http www iseoserrature it This symbol on the battery indicates that the battery has to be collected separately Dispose of batteries according to your local environmental laws and guidelines This sym...

Страница 14: ...acturer 15N maximum closing force 4 Suitability on use on fire smoke doors 0 F E suitable for use on smoke and fire door assemblies With a classification time of 90 min EI 90 5 Safety 0 0 no safety requirements 6 Corrosion resistance temperature humidity 0 P P no defined resistance 7 Security and drill resistance 1 7 7 very high security with drill resistance 8 Security electrical function 0 1 1 s...

Страница 15: ...Suitability on use on fire smoke doors B suitable for use on smoke and fire door assemblies 5 Safety 1 all panic exit devices have a critical safety function only the top grade is identified for the purpose of EN179 08 6 Corrosion resistance and temperature 4 very high corrosion resistance 240h temperature requirement from 10 C to 60 C 7 Security 5 5000 N 8 Projection of the operating element 2 pr...

Страница 16: ...cation suitable for iOS and Android smartphone Multistandard card tag reader 13 56Mhz RFID technology ISO14443A ISO14443B Mifare Classic Plus DesFire Single Action version anti panic version the internal handle retracts latch and deadbolts in one unique and smooth movement In this way the user can always open the door from the inside simply pushing on the handle even if the deadbolts are out DC ex...

Страница 17: ...e system system s initialization and plant code assignment RFID credentials Mifare cards tags ISEO cards tags Transponder with or without key inside Smartphone with Argo app Bluetooth 4 0 ready From iPhone 4s with iOS 7 and above Android phones from ver 5 0 External control modules with Keyboard and RFID RFID only Hidden RFID Reader 13 56Mhz RFID reader Keyboard for PIN codes Bluetooth 4 0 ready l...

Страница 18: ... and iOS Automatic software upgrade when an update is available your phone notifies you and the new software will be automatically installed in the lock from your phone Version Standard Single Action Mechanical dimensions Handle follower 8mm Backset 63mm Centre distance 85mm Functional modes 2 functional modes to be set by the end user by the Argo App Opening commands Bluetooth 4 0 by the Argo App...

Страница 19: ... Feature Dimensions Handle follower 8mm Backset 63mm Centre distance 85mm Overview For detailed commercial information please check x1RSmart catalogue and leaflet available on the web site http www iseoserrature it ...

Страница 20: ...put Or you can drive a motorized swing door operator or interface to a home automation system using the outputs relay built in into the lock In the next examples you can find the 3 main configurations named A B and C A Alkaline batteries powered B DC power supply via cable gland spring plus alkaline batteries as back up facultative C DC power supply via door sensor contacts plus alkaline batteries...

Страница 21: ... not necessary if Single Action version 3 Alkaline batteries 6x1 5V D type 4 Battery holder 5 External control module keyboard and RFID reader only RFID reader without keyboard or Hidden RFID reader All embeds the Bluetooth radio module 6 Master Card Set Overview Output relay cannot be used in this configuration since it requires a DC power supply by cable gland spring ...

Страница 22: ...ery holder 5 8 Pins Multifunction cable power supply remote opening command and relay output 6 Cable gland spring 7 Power supply 8 30Vdc 8 External control module keyboard and RFID reader only RFID reader without keyboard or Hidden RFID reader All embeds the Bluetooth radio module 9 Master Card Set Overview In this configuration it is possible and recommended to use in addition the alkaline batter...

Страница 23: ... it can be installed in the lock side or hinges side of the door 7 Power supply 8 30Vdc 8 External control module keyboard and RFID reader only RFID reader without keyboard or Hidden RFID reader All embeds the Bluetooth radio module 9 Master Card Set Overview In this configuration it is also possible to install the Door sensor contact 6 in the hinges side of the door For that an x1R specific code ...

Страница 24: ...24 Electrical connections standard Overview ...

Страница 25: ...de of the door an x1R specific code is required not standard solution For more info go to Door sensor contact paragraph To know more about Actuator mode go to x1R Smart as Actuator paragraph When the door is closed and safe bolts fully extended the relay normally closed contact NC is closed When the door opens the NC opens For more detailed information about the relay behavior go to Door status re...

Страница 26: ...Remote opening push button Blue Opto1 Orange Relay NO Green Relay COM Black GND Yellow Relay NC White Not used Red Vcc Brown Opto2 Ext power supply x1R power supply Green light bulb Red light bulb Relay contact type resistive 30Vdc ac 1A MAX Remote opening command power supply 8 30Vdc ac Light bulb power supply refer to its technical data 8 Poles Multifunction cable connector Overview 1 4 8 5 The ...

Страница 27: ...or Single Action version 4 Cylinder fixing screws kit 2 different screws 5 Installation guide IT UK Product identification Product is identified by a label in double copy attached to the box and to the lock case reporting all the information about product production and traceability 5 2 3 1 4 6 Jumper to use the lock as actuator for more information go to paragraph x1R Smart as actuator 6 ...

Страница 28: ...uct code is composed as follows 00069X XX XX 050 Getting started 9 Single Action 6 Standard Pistons projection mm 00 with faceplate 3 13 Pistons center distance mm 28 37 Different pistons projection measures can be done on request ...

Страница 29: ... of 4 and a maximum of 8 digits code confirmed by number sign Getting started For this operation refers to the Installation Guide included in the product box and available at link https app iseo com Argo Installation Guides This operation that keeps about 20 seconds is indicated to the user by the orange led in the external module continuously flashing Do not switch off x1R Smart during this opera...

Страница 30: ...light signals Getting started For the system s initialization use exclusively Master card 1 and put cards 2 and 3 in a safe place The use of Master cards 2 and 3 will be required only if Master Card 1 is lost or damaged All x1R Smart belonging to the same plant must be initialized or updated with the same Master Card To know more about Master Card read the Argo User Manual available at link https ...

Страница 31: ...o enter Programming Mode 2 The device emits 3 acoustic signals together with 2 green light signals 3 Read the Cards to add it to the User List 4 For each added Card the device emits 2 acoustic signals together with 2 green light signals to confirm the operation 5 At the end of the operation present again the Master Cards 1 to exit Programming Mode The device goes automatically out of Programming M...

Страница 32: ...er with 2 green light signals 3 Enter your PIN code from 4 to 14 characters and confirm by key 4 For each added code the device emits 2 acoustic signals together with 2 green light signals to confirm the operation 5 At the end of the operation present again the Master Card 1 to exit Programming Mode The PIN code must be minimum 4 characters to maximum of 14 characters The device goes automatically...

Страница 33: ... by the Bluetooth 4 0 technology 1 Download the free ISEO Argo application from the APP Store iOS or Google Play Android 2 Enable Bluetooth communication on your smartphone 3 Open the Argo app You will see in the smartphone display into a ray of 10mt the x1R Smart icon button identified by its serial number x1R Smart serial number Getting started ...

Страница 34: ...smartphone as credential to open Getting started 2 Tap Done to memorize your phone as opening Credential 1 Change the name of your phone The icon in the app become red Press it To know more about the in app pairing technology read the Argo User Manual available at https app iseo com ...

Страница 35: ...to the User List on your smartphone The last memorized credential is displayed on the top of the list 7 Press Door Info and then Door Name to change the device serial number into a real door name Tap to change the door name Added Mifare and ISEO cards or tag Added phone Users menu Door Info menu Getting started ...

Страница 36: ...o exit Programming Mode 9 Press the x1R Smart icon button to open by your phone Alternatively read the cards or tags previously memorized Press the icon button to open the door To know more about the Argo app read the Argo User Manual available at app iseo com Getting started ...

Страница 37: ...go app and the external numeric keypad Getting started 1 Present Master Card 1 to the reader to enter Programming Mode The icon in the app become red Press it 2 In the Use menu touch the add user icon 3 Touch PIN button To know more about Invitation refer to the Argo User Manual at app iseo com ...

Страница 38: ...ccess with Block Standard User function enabled 7 Touch Done to confirm the operation The PIN code appears in the User list in the PIN list with the assigned name For security reasons the PIN code is never visible neither in the Users list nor in the historical Events nor in the Dump Information To know more about VIP and Block Standard User function and Dump Information refer to Argo User Manual ...

Страница 39: ...g your smartphone and the Argo app 2 Using an authorized ISEO or Mifare card tag reading it by means of the external control module with keyboard or RFID reader only or by the hidden external reader 3 Using a PIN code previously stored in the User list by means of the external keyboard 4 Using the mechanical key 1 3 2 4 EXTERNAL SIDE ...

Страница 40: ...sent 3 Open by the internal handle if Single Action version 4 Use a remote opening command for example the intercom button by the optoisolated input 5 Use the mechanical key INTERNAL SIDE Basics 1 2 3 Single Action version 5 4 In case of electronic or power supply issues x1R Smart can always be opened from the internal and the external side by the mechanical key ...

Страница 41: ... shows the total number of users stored as phone card tag PIN or Invitations Up to a maximum of 300 users can be stored For more information about Invitation see the Argo User Manual at link https app iseo com Enable the automatic Passage Mode To know more about this function go to Argo User Manual available at web link app iseo com Master Card set and Master Card level in use See Advanced Functio...

Страница 42: ...e electronic boards composing x1R Smart x1R Smart main board software This is the most important software version upgradeable via Argo app Bluetooth radio module software version Main electronic board Serial number Internal control module software version External control module software version ...

Страница 43: ... This parameter shows the type of lock Single Action or Standard See detailed information in the related paragraph You can set the Passage Mode in Light or Free See detailed information in the related paragraph it is the elapsing time between the door closing action and the bolts physical movement starts It allows you to differently configure the internal relay behavior To know more about this fun...

Страница 44: ...R Smart version is defined also in the Argo app by a parameter that must always correspond to the lock code 000699xxxxxxxx Single Action 000696xxxxxxxx Standard This parameter is set from the factory but there is the possibility to change it only in the Advanced Setting menu just in case of needs For example spare part management troubleshooting test Advanced x1R Smart version must always correspo...

Страница 45: ...s bolts and latch to open the door This is set as default from the factory Outside Handle following an opening command the lock withdraws the bolts but not the latch Lower the outside handle to manually withdraw the latch to fully open the door Advanced Change from Outside Knob to Outside Handle and viceversa Outside Knob and Outside Handle respectively corresponds to the previous Argo Functional ...

Страница 46: ...actory In the electronic motorized locks for armoured doors market used in offices aplications common doors with high transit of people the door should not be always opened Free but closed only with the latch This state is called Light just because the lock not closing the bolts is not completely secure This solution is however very useful and effective in these contexts since it has the following...

Страница 47: ...default values originally set in the Argo app Tap this button to fully reset your doorlock This function is useful for example when you need to send back the device for repair and you need to remove the Master Card plant code from it A warning pop up will advise you that it will cause the removal of the Master Card and the cancellation of the entire user list All device parameters will come back t...

Страница 48: ... output relay changes every time door opens and closes Single pulse the output relay provides when opening a single pulse with duration equal to the value set in milliseconds in the Argo app The maximum programmable value is 1000msec 1sec Advanced The relay signal when opening changes state at the first bolts movement whether they are driven by electronic command internal handle or mechanical key ...

Страница 49: ...n This to be certain that door is fully free to be open when the swing door operator starts Advanced For the relay technical data go to paragraph Technical Data The NO contact behavior follows the relay status active and not active To get an example of relay connection wiring diagram go to paragraph Example of 8 Pins Multifunction Cable wiring scheme The relay behavior remains the same even with L...

Страница 50: ...n or concierge table This command can also be sent by an external control unit belonging to an home automation system alarm system or centralized opening system The remote opening command is connected to the optoisolated input into the 8 Poles Multifunction Cable connector pin 4 and 8 see paragraph Electrical Connection and can be done 1 By cable gland spring 2 By an additional Door contact sensor...

Страница 51: ...he remote opening button is released the bolts closes and the Passage Mode icon disappear from the Argo user interface The remote opening is recorded into the events log To get an example of the remote opening command wiring diagram go to paragraph Electrical connection and Example of 8 Pins Multifunction Cable wiring scheme The remote opening command must be always powered 8 30Vdc ac ...

Страница 52: ... the electronic of the lock when door is actually ajar Door sensor contact female To be installed in the fixed door frame in the lock side Door sensor contact male with adjustable spring contacts installed into the lock Advanced 1 Female Door sensor contact installed in the fixed frame of the door in the lock side to get the door ajar status 2 Power supply 8 30Vdc optional It is always possible to...

Страница 53: ...nsor contact with adjustable spring contacts installed in the hinge side of the door 2 Poles connector To be connected to x1R Smart 1 Female Door sensor contact to get the door ajar status It is installed in the hinge side of the door Connect the male door sensor contact to the 2 poles connector available in back of the lock 3 Power supply 8 30Vdc optional It is always possible to power the lock b...

Страница 54: ... next system components are not more used External control module with or without keyboard or hidden external control module both includes RFID reader and Bluetooth radio module Master card RFID credential such as ISEO or Mifare cards and tags The smartphone and as consequence the Argo app x1RSmart system components as actuator Components Description Features x1R electronic lock for security doors...

Страница 55: ... and related signal see paragraph device initialization Removing the jumper and power cycling the lock Power ON reset the lock comes back to the standard version Actuator mode disabled Advanced To use the lock as actuator fit the jumper in the first top position of JP1 connector pins 1 and 2 JP1 After inserting or removing the jumper switch off and on the lock to make the changes effective A NOT i...

Страница 56: ...le connected Of course they cannot longer be modified since the external control module which includes the Bluetooth radio is no more present Actuator mode and door status relay In the Actuator mode the relay behaviour described at paragraph Door status relay is exactly the same It remains as provided from the factory or as configured by Argo before enabling the Actuator mode fitting the jumper As...

Страница 57: ... available at https app iseo com You can find explained the next important functions Battery levels Software upgrade Updating of Master Card level Master Cards set replacement and updating of system code Operations summary without Argo app Argo app error messages Lights and acoustic signals And much more Advanced ...

Страница 58: ...go app the button shows the battery level icon At the first battery low signal replace the battery as soon as possible Battery level icon there are 4 battery levels The battery level is also shown in the Door Info menu Battery replacement does not affect Events and data stored in the Users list ...

Страница 59: ...tery replacement does not affect the data stored in the User list 1 Find the battery pack position This depends on door manufacturer Usually it is installed in the front side of the door up or down In other cases it can be placed in the top side of the door or even in the hinge side 2 Remove the 2 cross screw that secure the battery pack 3 Remove the battery pack disconnecting the 2 poles connecto...

Страница 60: ...his date need to be written and remembered because it will probably be the replacing batteries date indicatively 6 7 years To check the battery real charge proceed as follows 1 Disconnect the external power supply cable from x1R Smart so that it is only battery powered 2 Open the lock by your smartphone 3 Check the battery charge by Argo app look at the opening icon button or in the Door Info menu...

Страница 61: ...with chemicals such as alcohol thinners benzene acidic or alkaline solvent cleaners abrasive cleaners or lubricants as these may damage the device s finish and cause discoloration Storage If x1R Smart will not be used for an extended period remove the battery and store the battery in a cool dry area taking care that terminals doesn t touch any conductive object or part Store x1R Smart in a clean d...

Страница 62: ...ey Bolts have been moved by key but not completely in Just 1 shot half way Lock not close due to motor extra current error It happens when there is an excessive friction of latch or bolts during closing Lock not close due to sensor time out error It may happen when motor does not engage the mechanic during closing Lock not open due to motor extra current error It happens when there is an excessive...

Страница 63: ...ware Reset Doorlock to Factory mode succesfull Full device reset has been performed Device is no more initialized and the user list is clean Events are still present Restore Default Doorlock Setting succesfull Restore of default setting has been performed The device is still initialized but all settings come back to the factory default Single Action Change x1R Smart version has been changed from S...

Страница 64: ...The green led is flashing n times until the door opening or until the end of the opening time Added credential Only in Programming Mode Door closed and safe Physical closing of door Credential not in memory Card tag or PIN never stored into the lock user list Opening not allowed Credential already programmed Credential in the user list but user not enabled I e Block Standard User Only in Programmi...

Страница 65: ...ly maximum distance mt Minimum power supply Vdc Minimum wire gauge mm2 in relation to the power supply External power supply 2mt 10 0 75 5mt 12 0 75 10mt 12 1 20mt 12 1 5 Remote opening command 100mt 9 0 3 Door status relay Wiring specifications depends on relay characteristics see paragraph Technical Data and on the operating characteristics of the circuit or system controlled by the relay Append...

Страница 66: ...cally shoot the bolts when closing An external handle is required to manually withdraw the latch and an electronic command is required to manually shoot the bolts Outside Handle enable Light mode disable Light Mode to shoot the bolts by phone card tag PIN 5 The lock withdraws only the latch when opening and will not automatically shoot the bolts when closing The bolts can only be moved using the m...

Страница 67: ... to the Warnings section If the problem has not solved call the IseoZero1 Technical Support x1R does not close or open the motor sounds like strives doing the operation After 3 attempts the lock gives an acoustic and light signal error Bolts or latch cannot enter or exit from their seat The lock tries 3 times then stop The events log reports Lock open close with motor extra current error Check if ...

Страница 68: ...he pressure of the door sealing x1R does not respond to any command Latch and bolts doesn t move The command modules have led OFF and doesn t give any sound Connection error message when opening by phone x1R not powered Check batteries status Check main power supply if present Check the power supply cable if properly connected and not damaged and check if connector is broken or has false contacts ...

Страница 69: ...ble Block Standard User function by Argo app As soon as I open the door the lock switches off control modules led OFF Lock powered by Door sensor contacts and battery low Replace batteries x1R is not visible on Argo app The external and internal module is flashing red at regular interval without any sound Bluetooth module not connected or not working Check the Bluetooth module cable if intact and ...

Страница 70: ...70 Notes ...

Страница 71: ...71 Notes ...

Страница 72: ...72 x1RSmart_User Manual_EN_02_20180615 Not contractual document Subject to change 2018 Iseo Serrature S p a ...

Отзывы: