Maintenance
ISARIA PRO Compact
®
9.2
Possible errors and how to fix them
9.3
Repair instructions
See chapter 4.2 page 10
10
Maintenance
Regular cleaning
- Sensor surfaces of R sensor
- Sensor (dome) of E sensor
All other components are maintenance free.
See section, figure/page
Error
Cause/solution
▼
Output fertiliser quantity does not
correspond to the displayed
(calculated) values
- Manual operation is activated/switch on automatic
operation
fig. 33 / 39
- No task has been started/start task
7.4 / 28
- Fertiliser content per kg of application quantity is set
incorrectly/
7.8.1 / 34
- Incorrect quantity unit selected/check and, if need
be, correct
- R sensor is incorrectly aligned/check both sensors
and brackets and adjust correctly
5.1 / 14
- R sensor is dirty/clean sensor measurement surface
- Driving speed so high that the application device
cannot output the calculated quantity/adjust driving
speed
- Application device switched off/switch on
- Communication with application device has been
interrupted/check ISOBUS connection of application
device
No organisational data can be
entered
USB stick not inserted/insert USB stick
7.7 / 30
Green LED on E sensor (It. 1) is
not lighting up
Both R sensors are not providing measurements
fig. 3 / 8