7.12
Output of fertiliser
7.12.1 Automatic operation
In automatic operation* (notification (2, fig. 33)) the application quantity can be adjusted at any time
during the fertilisation run (for preparation see 7.2 / 24). For this, increase (A) or lower (B) the range.
The value can be read from (C).
To prevent over-fertilisation, the application device must be regularly monitored (see 4.5.3
/ 13).
7.12.2 Manual operation
In manual operation* (notification (3, fig. 33)) the application quantity is not regulated. The field (site-
specific) is uniformly supplied with fertiliser. The set “target quantity” is output uniformly across the
field (site-specific). The application device is operated with the fixed value of the “target quantity”.
The sensor values remain unconsidered.
* Button for switching between manual and automatic operation (D)