background image

27

EN

  

METRO’

USE AND MAINTENANCE MANUAL

428000375

237

PASTRY DISPLAY CABINETS

If the appliance is not working properly or stops working, before contacting the Technical Assistance 

service intervention check the following: 

FAILURE

CAUSE

SOLUTION

The appli-

ance is not 

working

Blown protective fuse

Find what triggered the 

switch and subsequently replace the fuse.

The master switch is open

Close the master switch.

Plug is not inserted 

Insert the plug.

Power cut

If the power cut persists, 

transfer the product to a freezer.

The internal 

temperature 

is not low 

enough

Evaporator(s) completely blocked 

by ice

Carry out an additional defrosting cycle.

The wrong temperature has been 

set on the electronic control board

Set the right temperature.

The equipment is affected by 

draughts or is exposed to direct or 

refl ected sunlight

Eliminate any excessive draughts and prevent any direct or re-

fl ected sunlight.

Insuffi cient cooling air fl ow in the 

air condensing unit

Remove anything that may affect air fl ow inside the condensing 

unit (paper sheets, cardboard, grids with an insuffi cient number 

of holes, etc.).

The internal fans have stopped 

or their blades are damaged

Contact the Technical Assistance service.

Internal ventilation is too high

Contact the Technical Assistance service.

Low electronic control board ef-

fi ciency

Contact the Technical Assistance service.

Replace electronic control unit.

Replace the temperature probes only after checking which of the 

two is not operating effi ciently.

Air condensing unit blocked by dust 

or debris

Contact the Technical Assistance service. 

Clean the condensing unit thoroughly.

Insuffi cient coolant

in the cooling system 

Contact the Technical Assistance service.

Find the cause behind the lower amounts of coolant and eliminate 

it. Top up the coolant. If necessary, empty the system before 

topping up. 

The com-

pressor does 

not work or 

works only 

for 

a few mo-

ments

No power supply

Check if there is a power cut.

Close the various switches on the power supply line.

The power supply voltage is too 

low

Check that the mains voltage at the ends of the power supply 

cable is 220V +/- 10%.

The temperature set on the

thermostat is too high

If the set temperature is higher than that of the air in the display 

area, the compressor does not activate itself.

Set a more suitable temperature if the current value is not low 

enough.

The pressure switch 

(if any)

 was 

activated at maximum pressure

Contact the Technical Assistance service. 

Check the reasons why the pressure switch is operating at 

maximum pressure levels, such as: air condensing unit blocked, 

condensing unit fan stopped, ambient temperature too high, 

pressure switch broken.

10. TECHNICAL ASSISTANCE

10.1 Faults

Содержание METRO RV LS 93

Страница 1: ...AINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS ISA S r l Via del Lavoro 5 06083 Bastia Umbra Perugia Italy Tel 39 075 80171 Fax 39 075 8000900 www isaitaly com METRO 93 N VA RV VA RV LS 129 N...

Страница 2: ...positioning and ambient conditions 10 4 3 Electrical connection 10 5 TECHNICAL SPECIFICATIONS 11 5 TECHNICAL SPECIFICATIONS N VA 12 5 TECHNICAL SPECIFICATIONS RV VA 13 5 TECHNICAL SPECIFICATIONS RV LS...

Страница 3: ...manual contains symbols to attract the reader s attention and highlight particularly important aspects The table below illustrates the meaning of the various symbols used Read the instructions manual...

Страница 4: ...peration Before doing any type of work disconnect the equipment from the power supply Any work on electric and electronic parts or cooling system components should only be carried out by trained perso...

Страница 5: ...safety systems operations how to use the instruments and the interpretation of any diagnostics reports main procedures and information relating to routine maintenance For correct use of the equipment...

Страница 6: ...nel in compliance with current laws 2 1 Personnel training The buyer is responsible for ensuring personnel who will use the equipment and maintenance technical staff are instructed and trained adequat...

Страница 7: ...fitted with the aforementioned safety devices there are still some risks that cannot be eliminated but reduced via corrective actions by the final integrator and correct operational procedures Below...

Страница 8: ...Slipping Any leaks in the areas surrounding the equipment may cause personnel to slip Check that there are no leaks and keep these areas clean at all times 2 3 5 Tripping Generally untidy deposits of...

Страница 9: ...arts doors sliding doors glass parts etc and group the various materials according to their features 6 Check the type of coolant on the label located inside the counter Remove the coolant and dispose...

Страница 10: ...osition the equipment away from sources of heat radiators all types of ovens etc and away from draughts generated for example by fans air conditioning ducts etc Also avoid direct exposure to sunlight...

Страница 11: ...EN 60335 2 89 N C ambient 5 43 5 43 Refrigerant GWP R404A 3784 R404A 3784 Power supply V ph Hz 230 1 50 230 1 50 Electric absorption standard W A 1270 6 5 1500 6 7 Electric absorption defrosting W A 4...

Страница 12: ...12 METRO USE AND MAINTENANCE MANUAL 428000375237 EN PASTRY DISPLAY CABINETS 5 TECHNICAL SPECIFICATIONS...

Страница 13: ...13 EN METRO USE AND MAINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS 5 TECHNICAL SPECIFICATIONS...

Страница 14: ...14 METRO USE AND MAINTENANCE MANUAL 428000375237 EN PASTRY DISPLAY CABINETS 5 TECHNICAL SPECIFICATIONS...

Страница 15: ...NETS 5 1 Installation Attention The distances mm indicated for correct equipment installation must be respected 5 2 Positioning Warning The equipment is fitted with height adjustable feet It is absolu...

Страница 16: ...tion The weight limits indicated for each shelf must be respected to avoid their deformation or breaking 5 4 Load limits Attention It is essential not to exceed the indicated load limits in order to p...

Страница 17: ...17 EN METRO USE AND MAINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS 5 6 Adjusting shelves The display shelves are adjustable in height as indicated below...

Страница 18: ...ct for its intended use The equipment consists of Insulated structure in ecological polyurethane Cooling system Electronic commands panel Electrical system On board condensing unit Shelf lighting Heig...

Страница 19: ...28000375237 PASTRY DISPLAY CABINETS 7 CONTROL PANEL The control panel consists of the following components 1 Electrical socket 2 Electronic Control Unit 3 Lighting switch MODELS 93 RV LS 93 RV VA 129...

Страница 20: ...or decreases their value when in programming Switches instrument on or off 7 2 User Interface XR44CX Attention The electronic control board is installed already programmed Any changes to the control...

Страница 21: ...aning On Compressor s active Flashing Delay against close start ups On Defrosting in progress Flashing Dripping in progress On A temperature alarm has occurred On Continuous cycle in progress On Energ...

Страница 22: ...perature display Set Point modification Press for at least 2 seconds Set point is displayed and LED C starts flashing Modify value by acting on keys and Memorise new set point by pressing or wait 15 s...

Страница 23: ...OWN Scrolls menu options Decreases the values STAND BY ESC Goes back one level compared to current menu Confirms parameter value Activates the Stand by function SET ENTER Accesses the Setpoint Accesse...

Страница 24: ...nfirmed and the previous display will be restored Check UP Alarms are reported by the buzzer if any and the LED corresponding to the alarm icon Any alarms deriving from broken probe probe 1 appear dir...

Страница 25: ...drainage channel If the equipment is not connected to a drain channelled into the ground follow the procedure described in the previous paragraph The water used to rinse the solution should be collec...

Страница 26: ...e and Necessity User Power supply cable electric sockets and or plugs check Monthly Six monthly User Check the seal gaskets integrity Monthly User Condenser cleaning Monthly Six monthly Technical Assi...

Страница 27: ...he Technical Assistance service Low electronic control board ef ficiency Contact the Technical Assistance service Replace electronic control unit Replace the temperature probes only after checking whi...

Страница 28: ...ctivated ETc RTF Real time clock is broken Contact the Technical Assistance service Reset the clock If the alarm does not stop replace the clock EE Machine parameter error Contact the Technical Assist...

Страница 29: ...RV VA BT1 Temperature probe EV3 Condenser fan BT2 Defrosting probe EV4 Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor HL LED EH2 Heating resistor fro...

Страница 30: ...Defrosting probe EV4 Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor T1 Transformer EH3 Outside...

Страница 31: ...enser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor MS2 Compressor EH3 Outside perimeter heating resisto...

Страница 32: ...rosting probe EV3 Condenser fan CE1 Electronic control board EV4 Condenser fan EH1 Outside perimeter heating resistor FA1 EMC fi lter EH2 Outside perimeter heating resistor MS1 Compressor EH3 Outside...

Страница 33: ...ng probe EV4 Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor T1 Transformer EH3 Outside perimete...

Страница 34: ...Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor MS2 Compressor EH3 Outside perimeter heating res...

Страница 35: ...35 EN METRO USE AND MAINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS FA1 EMC fi lter QSI Main switch GD Power supply LED HL LED Attachment 7 93 N VA 129 N VA...

Страница 36: ...cal File 11514 September 2011 and CEI EN 61000 3 3 CEI 210 96 Electromagnetic Compatibility EMC Part 3 Limits Section 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for...

Страница 37: ......

Страница 38: ......

Отзывы: