4. INSTALLATION

This manual provides information on how to unpack, 

position and connect to the power supply.

4.1 Storage and unpacking

The equipment, with or without the packaging, should be carefully stored inside warehouses 

or in areas away from the elements and direct sunlight, at a temperature between 0 and 

+40°C.

 

The equipment should only be moved by qualifi ed personnel operating forklift trucks, the 

power of which should be suited to handling the weight of the product: during this operation 

the equipment MUST be placed on the special pallet supplied.

Unpack the equipment by removing the screws fi xing it to the pallet.

All packaging materials are recyclable and should be disposed of in accordance with local 

regulations. Please destroy "plastic" bags to prevent them from becoming hazardous to 

children (suffocation).

4.2 Installation, positioning and ambient conditions

Attention

There should be a good air fl ow around the compressor and condensing unit. Therefore the area 

around the unit should not be obstructed by boxes or other objects.

Position the equipment away from sources of heat (radiators, all types of ovens, etc.), and away from 

draughts (generated for example by fans, air conditioning ducts, etc.). 

Also avoid direct exposure to sunlight, or anything that causes the temperature inside the cabinet to 

rise with detrimental results to unit operation and energy consumption. Do not use the equipment 

outdoors and do not leave it exposed to rain.

4.3 Electrical connection

Attention

Check that the voltage indicated on the appliance is the same as the value on the appliance 

identifi cation label and in the table provided in paragraph 2 of this manual, and check that the 

required voltage is suitable. 

Check on the socket that the power supply voltage provides rated voltage (±10%) when the 

compressor is started.

The plug should be directly connected to the electrical socket. It is forbidden to connect the plug to 

the socket by means of multiple socket extensions or adaptors.

The electrical system socket must be fi tted with a disconnecting device from the mains (rated for the 

load and conform to current standards) to guarantee full disconnection in overloads category III (3) 

and ensure protection of the circuits from earth faults, overloads and short circuits.

Do not route the electricity cable in passageways.

Attention

Earthing is necessary and mandatory by law.

Содержание METRO RV LS 93

Страница 1: ...AINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS ISA S r l Via del Lavoro 5 06083 Bastia Umbra Perugia Italy Tel 39 075 80171 Fax 39 075 8000900 www isaitaly com METRO 93 N VA RV VA RV LS 129 N...

Страница 2: ...positioning and ambient conditions 10 4 3 Electrical connection 10 5 TECHNICAL SPECIFICATIONS 11 5 TECHNICAL SPECIFICATIONS N VA 12 5 TECHNICAL SPECIFICATIONS RV VA 13 5 TECHNICAL SPECIFICATIONS RV LS...

Страница 3: ...manual contains symbols to attract the reader s attention and highlight particularly important aspects The table below illustrates the meaning of the various symbols used Read the instructions manual...

Страница 4: ...peration Before doing any type of work disconnect the equipment from the power supply Any work on electric and electronic parts or cooling system components should only be carried out by trained perso...

Страница 5: ...safety systems operations how to use the instruments and the interpretation of any diagnostics reports main procedures and information relating to routine maintenance For correct use of the equipment...

Страница 6: ...nel in compliance with current laws 2 1 Personnel training The buyer is responsible for ensuring personnel who will use the equipment and maintenance technical staff are instructed and trained adequat...

Страница 7: ...fitted with the aforementioned safety devices there are still some risks that cannot be eliminated but reduced via corrective actions by the final integrator and correct operational procedures Below...

Страница 8: ...Slipping Any leaks in the areas surrounding the equipment may cause personnel to slip Check that there are no leaks and keep these areas clean at all times 2 3 5 Tripping Generally untidy deposits of...

Страница 9: ...arts doors sliding doors glass parts etc and group the various materials according to their features 6 Check the type of coolant on the label located inside the counter Remove the coolant and dispose...

Страница 10: ...osition the equipment away from sources of heat radiators all types of ovens etc and away from draughts generated for example by fans air conditioning ducts etc Also avoid direct exposure to sunlight...

Страница 11: ...EN 60335 2 89 N C ambient 5 43 5 43 Refrigerant GWP R404A 3784 R404A 3784 Power supply V ph Hz 230 1 50 230 1 50 Electric absorption standard W A 1270 6 5 1500 6 7 Electric absorption defrosting W A 4...

Страница 12: ...12 METRO USE AND MAINTENANCE MANUAL 428000375237 EN PASTRY DISPLAY CABINETS 5 TECHNICAL SPECIFICATIONS...

Страница 13: ...13 EN METRO USE AND MAINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS 5 TECHNICAL SPECIFICATIONS...

Страница 14: ...14 METRO USE AND MAINTENANCE MANUAL 428000375237 EN PASTRY DISPLAY CABINETS 5 TECHNICAL SPECIFICATIONS...

Страница 15: ...NETS 5 1 Installation Attention The distances mm indicated for correct equipment installation must be respected 5 2 Positioning Warning The equipment is fitted with height adjustable feet It is absolu...

Страница 16: ...tion The weight limits indicated for each shelf must be respected to avoid their deformation or breaking 5 4 Load limits Attention It is essential not to exceed the indicated load limits in order to p...

Страница 17: ...17 EN METRO USE AND MAINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS 5 6 Adjusting shelves The display shelves are adjustable in height as indicated below...

Страница 18: ...ct for its intended use The equipment consists of Insulated structure in ecological polyurethane Cooling system Electronic commands panel Electrical system On board condensing unit Shelf lighting Heig...

Страница 19: ...28000375237 PASTRY DISPLAY CABINETS 7 CONTROL PANEL The control panel consists of the following components 1 Electrical socket 2 Electronic Control Unit 3 Lighting switch MODELS 93 RV LS 93 RV VA 129...

Страница 20: ...or decreases their value when in programming Switches instrument on or off 7 2 User Interface XR44CX Attention The electronic control board is installed already programmed Any changes to the control...

Страница 21: ...aning On Compressor s active Flashing Delay against close start ups On Defrosting in progress Flashing Dripping in progress On A temperature alarm has occurred On Continuous cycle in progress On Energ...

Страница 22: ...perature display Set Point modification Press for at least 2 seconds Set point is displayed and LED C starts flashing Modify value by acting on keys and Memorise new set point by pressing or wait 15 s...

Страница 23: ...OWN Scrolls menu options Decreases the values STAND BY ESC Goes back one level compared to current menu Confirms parameter value Activates the Stand by function SET ENTER Accesses the Setpoint Accesse...

Страница 24: ...nfirmed and the previous display will be restored Check UP Alarms are reported by the buzzer if any and the LED corresponding to the alarm icon Any alarms deriving from broken probe probe 1 appear dir...

Страница 25: ...drainage channel If the equipment is not connected to a drain channelled into the ground follow the procedure described in the previous paragraph The water used to rinse the solution should be collec...

Страница 26: ...e and Necessity User Power supply cable electric sockets and or plugs check Monthly Six monthly User Check the seal gaskets integrity Monthly User Condenser cleaning Monthly Six monthly Technical Assi...

Страница 27: ...he Technical Assistance service Low electronic control board ef ficiency Contact the Technical Assistance service Replace electronic control unit Replace the temperature probes only after checking whi...

Страница 28: ...ctivated ETc RTF Real time clock is broken Contact the Technical Assistance service Reset the clock If the alarm does not stop replace the clock EE Machine parameter error Contact the Technical Assist...

Страница 29: ...RV VA BT1 Temperature probe EV3 Condenser fan BT2 Defrosting probe EV4 Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor HL LED EH2 Heating resistor fro...

Страница 30: ...Defrosting probe EV4 Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor T1 Transformer EH3 Outside...

Страница 31: ...enser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor MS2 Compressor EH3 Outside perimeter heating resisto...

Страница 32: ...rosting probe EV3 Condenser fan CE1 Electronic control board EV4 Condenser fan EH1 Outside perimeter heating resistor FA1 EMC fi lter EH2 Outside perimeter heating resistor MS1 Compressor EH3 Outside...

Страница 33: ...ng probe EV4 Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor T1 Transformer EH3 Outside perimete...

Страница 34: ...Condenser fan CE1 Electronic control board FA1 EMC fi lter EH1 Outside perimeter heating resistor MS1 Compressor EH2 Outside perimeter heating resistor MS2 Compressor EH3 Outside perimeter heating res...

Страница 35: ...35 EN METRO USE AND MAINTENANCE MANUAL 428000375237 PASTRY DISPLAY CABINETS FA1 EMC fi lter QSI Main switch GD Power supply LED HL LED Attachment 7 93 N VA 129 N VA...

Страница 36: ...cal File 11514 September 2011 and CEI EN 61000 3 3 CEI 210 96 Electromagnetic Compatibility EMC Part 3 Limits Section 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for...

Страница 37: ......

Страница 38: ......

Отзывы: