IRT IRT-6630-DTR Скачать руководство пользователя страница 18

 

IRT-6630-DTR 

I.R.T. Communications Pty Ltd | www.irtcommunications.com 

 

 

Page 18 of 22

 

Revision 01 

 

(12)

 

nonUrg-ValidSignalAbsent-OpticalLow:  Either  no  valid  signal  is  present  on  the 
input  to  the  transmitter  or  received  by  the  receiver  and  optical  detector  of 
receiver is reporting that the optical input signal is approaching its minimum, or 
has  exceeded  its,  allowable  signal  strength. 

NOTE:

  Detectors  can  vary  in  their 

reporting  of  optical  low  state.  It  is  recommended  to  confirm  that  the  received 
signal is error free if an Optical Low alarm has been raised. 

(13)

 

urgent-1-OpticalFail-nonUrg-validSignalAbsent-opticalLow:  Transmitter  laser  has 
failed and no valid signal has been received by the receiver and optical detector 
of receiver is reporting that the optical input signal is approaching its minimum, 
or has exceeded its, allowable signal strength. 

NOTE:

 Detectors can vary in their 

reporting  of  optical  low  state.  It  is  recommended  to  confirm  that  the  received 
signal is error free if an Optical Low alarm has been raised. 

(14)

 

urgent-2-OpticalFail-nonUrg-validSignalAbsent-opticalLow: Not applicable to the 
IRT-6630-DTR. 

(15)

 

urgent-1-2-OpticalFail-nonUrg-ValidSignalAbsent:  Both  transmitter  laser  has 
failed and optical input to the receiver’s detector is below its minimum threshold 
or  has  failed  and  no  valid  signal  is  present  on  the  input  to  the  transmitter. 
Duplicate entry for table structure only. 

 

irt663xDxxSettingsTable: 

A table containing configuration settings for all IRT-6630-DTR cards at this node. 

 

controlMode

 

-  An indication of the control settings made as per the PCB DIP switch setting: 

(0)

 

dashboardSNMP: Card settings can be controlled via DashBoard™ or SNMP. 

(1)

 

pcbSwitches: Card settings as per DIP switch settings only. 

(2)

 

lockedtoDashboardSNMP:  Lock  module  to  DashBoard™  or  SNMP  control  – 
overrides SW1-7 position. Note that SW1-7 must be initially ON to be able to set 
to Lock to SNMP mode. To release send either a (0) or (1). 

 

ioAlarmTrapEnable

 

-  An indication and control of Trap enable/disable function of input/output alarms: 

(0)

 

ioAlarmTrapDisable: Disable input/output alarm Traps. 

(1)

 

ioAlarmTrapEnable: Enable input/output alarm Traps. 

 

reset

 

-  Unit reset control: 

(0)

 

normal: when queried reset control returns a ‘normal’ state. 

(1)

 

reset: system reset causes a reset of the card. 

 

autoChangeOver

 

-  Enable or Disable Automatic Changeover to switch Tx optical output from primary (IN 1) 

to  secondary  (IN  2)  input  on  loss  of  valid  primary  input  (if  secondary  input  is  both 
present and valid): 

(1)

 

disable: Automatic Changeover mode disabled. 

(2)

 

enable: Automatic Changeover mode enabled. 

 

monitorPort

 

-  Sets the signal source for BNC OUT 1: 

(0)

 

receiverInput: OUT 1 port outputs the received signal. 

(1)

 

transmitterOutput: OUT 1 port outputs the transmitted signal. 

(2)

 

transmitterOutput:  Not  applicable  to  IRT-6630-DTR.  Defaults  back  to 
receiverInput (0). 

(3)

 

cableInputs: Not applicable to IRT-6630-DTR. Defaults back to transmitterOutput (1). 

 

keepAliveTx1

 

-  A substitution of a 54 MHz signal in place of no input signal to keep the optical link active 

at the receiver end: 

(1)

 

enable: Keep Alive signal enabled. 

(2)

 

disable: Keep Alive signal disabled. 

 

keepAliveTx2

 

Not applicable to the IRT-6630-DTR. 

 

optical1TrapEnable

 

-  An indication and control of Trap enable/disable function of the transmitter laser state: 

(0)

 

disable: Disable laser Trap alarms. 

(1)

 

enable: Enable laser Trap alarms. 

 

optical2TrapEnable

 

-  An indication and control of Trap enable/disable function of the receiver input state: 

(0)

 

disable: Disable receiver Trap alarms. 

(1)

 

enable: Enable receiver Trap alarms. 

Содержание IRT-6630-DTR

Страница 1: ...IRT 6630 DTR I R T Communications Pty Ltd www irtcommunications com Page 1 of 22 Revision 01 User Manual 3G HD SD SDI ASI Fibre Optic Transceiver...

Страница 2: ...age 2 of 22 Revision 01 3G HD SD SDI ASI Fibre Optic Transceiver Revision History Revision Date By Change Description Applicable to 00 29 07 2014 AL Original Issue Firmware Revision 1 0 01 07 02 2018...

Страница 3: ...Switch Settings 8 Installation 9 Signal Connections 9 Fibre Optics Connection 9 Front Edge LED and Switch Locations 10 Rear Assembly Layouts 11 Operation 12 Figure 1 Attenuation versus wavelength 13...

Страница 4: ...ions are observed All internal adjustments should only be made by suitably qualified personnel All operational adjustments are available externally without the need for removing covers or use of exten...

Страница 5: ...pengear tv that allows the user to remotely monitor and control an openGear type card fitted within an openGear frame that meets the openGear standard for DashBoard control A link is also supplied via...

Страница 6: ...le mode fibres Being independent from each other the transmit and receive signals can be of mixed signal types Optionally a 1310 1550nm WDM2 3 optical combiner can be fitted to allow for combined use...

Страница 7: ...t monitor Optical Optical output 0 dBm 4 5 0 dB CWDM DFB laser Optical input APD detector 9 to 27 dBm input level at 3G SDI typically 30 dBm at HD SD SDI Available wavelengths 1310nm or 1550nm Other w...

Страница 8: ...1 5 OFF Enable Laser laser is always enabled keep link alive signal when no input signal is present ON Auto Laser laser is enabled only when an input signal is present SW1 6 OFF Enable automatic input...

Страница 9: ...angeover is disabled and IN 2 is ignored With DIP switch SW1 8 OFF the OUT 1 BNC connector acts as an optical receiver section output OUT 2 is always an output of the optical receiver section With DIP...

Страница 10: ...ion is restored on resumption of power If the default Reset Switch is pressed whilst powering or inserting the card the card will default to factory preset settings Tx Laser Present Green Failure Red...

Страница 11: ...7 Beware that when in DashBoard or SNMP modes it is possible for an operator to easily switch between states for monitoring what is both being transmitted and received therefore OUT 2 should be used...

Страница 12: ...laser is set for permanent operation on loss of an input signal a 54MHz oscillator is switched into the optical output so that the optical receiver still recognizes the optical link as being valid Th...

Страница 13: ...cated by the green illuminated LASER LED Optical present optical low and optical input failure on the IRT 6630 DTR is indicated by a bi colour illuminated OPTICAL LED In this example the OPTICAL LED i...

Страница 14: ...manual is also downloadable from the openGear website IRT 6630 DTR DashBoard Screenshots Basic Tree View On the left the basic tree view shows the frame With the tree structure expanded a list of card...

Страница 15: ...oth the transmitter s laser Optical 1 and the receiver s detector Optical 2 The signal status of both the transmitter and receiver are also shown The Alias name of the transmitter inputs Channel Tx Ch...

Страница 16: ...port for the transmitter or a second receiver output Beware that because when in DashBoard mode it is possible for the operator to easily switch between states for monitoring the OUT 1 BNC port of wha...

Страница 17: ...icalFail Optical input to the receiver s detector is below its minimum threshold or has failed 3 urgent 1 2 OpticalFail Both transmitter laser has failed and optical input to the receiver s detector i...

Страница 18: ...hBoard or SNMP 1 pcbSwitches Card settings as per DIP switch settings only 2 lockedtoDashboardSNMP Lock module to DashBoard or SNMP control overrides SW1 7 position Note that SW1 7 must be initially O...

Страница 19: ...transmitter output GOOD FAIL optical2Component Detector type information about the receiver section 1 nm1470Laser Not applicable to the IRT 6630 DTR 2 nm1490Laser Not applicable to the IRT 6630 DTR 3...

Страница 20: ...iver channel 1 disabled Disable the receiver output Writing either a 2 3 4 or 5 will enable the output 2 enabledActive Receiver output is enabled and active 3 enabledMuted Receiver output is enabled a...

Страница 21: ...i3G HD SD ASI Reclocker set for 3G HD SD SDI ASI rates 2 sdiHD SD ASI only Reclocker set for HD SD SDI ASI rates only 3G SDI blocked 3 sdiSD ASI only Reclocker set for SD SDI ASI rate only 3G SDI HD S...

Страница 22: ...ure Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be servi...