IRT-6630-DTR
I.R.T. Communications Pty Ltd | www.irtcommunications.com
Page 16 of 22
Revision 01
Config TAB:
Under the Configuration TAB parameters such as Product Alias (name) and channel names (Channel Tx, Channel Rx
& Channel Tx2) can be user set. Click computer mouse into the field to change and type new name.
If DIP switch SW1-7 has been set for DashBoard™ control, parameters such as the transmitter and receiver data
rates can be set as well as Auto Change Over mode to automatically switch to input 2 on loss of input 1, and
whether the OUT 1 output acts as a monitor port for the transmitter or a second receiver output.
Beware that because when in DashBoard™ mode it is possible for the operator to easily switch between states for
monitoring the OUT 1 BNC port of what is both being transmitted and received, OUT 2 should be used as the
dedicated receiver output.
Under DashBoard™ control it is also possible to lock the control mode to DashBoard™ control. Even if the board is
subsequently switch to operate in the PCB mode, these settings will not have any effect until the control mode has
been release from the LockToDashBoard mode.
When in the PCB mode of operation, the Config TAB control functions are disabled, with the exception of the Alias
and Trap settings. All configuration parameters are then as per the DIP switch settings.