TECHNICAL SPECIFICATIONS

 

 

 

Video input characteristics: 

Input Signal Level

 

1 Vp-p. 

Input Impedance

 

Bridging 75 Ohms, Loop through. 

Return loss

 

>46 dB to 4.3 MHz. 

Number of Inputs

 

10. 

Input Connectors

 

BNC. 

 

Video expansion input characteristics: 

Input Signal Level

 

1 Vp-p. 

Input Impedance

 

75 Ohms terminated. 

Return loss

 

>46 dB to 4.3 MHz. 

Number of Inputs

 

1. 

Input Connectors

 

BNC. 

 

Transfer Characteristics: 

Overall Gain

 

Unity 

Frequency Response

 

±

 0.1 dB to 10 MHz (0.5V p-p Sweep Signal) 

Differential Gain

 

<0.2% (10-90% APL) at 4.43 MHz 

Differential Phase

 

<0.2 degrees (10-90% APL) at 4.43 MHz 

Crosstalk

 

<65 dB to 4.43 MHz 

 

Video output characteristics: 

Output signal level

 

1 Vp-p 

Number of outputs

 

Output impedance

 

75 Ohms 

Isolation

 

>36 dB to 4.3 MHz 

Noise at the outputs

 

70 dB below 1V p-p 

Output connectors

 

BNC. 

 

Control inputs/outputs: 

Switching time

 

During the vertical interval. Timing is derived from the output video 

Type

 

4/5  bit  parallel  TTL  level  signal  compatible  with  IRT  VA-400  video 
switcher tally output circuit and IRT 3000 series switchers. 

Number

 

1 “input” & 1 “output”. 

Connectors

 

25 pin 'D' - female. 

 

Power requirements:

 

110, 130, 220 / 240 Vac 50 / 60 Hz 10 VA. 

Fuse rating:  240 Vac

 

250 mA slow blow. 

 

110 Vac

 

500 mA slow blow. 

 

Other: 

Temperature range

 

0 - 50° C ambient 

Mechanical

 

IRT  19"  rack  chassis  with  input,  output  and  power  connections  on  the 
rear panel. 

Finish: 

Front panel

 

Grey enamel, silk screened black lettering & red IRT logo 

 

Rear panel

 

Silk screened bright passivated steel, silk screened black lettering. 

Dimensions

 

44 mm x 480 mm x 230 mm. 

 

Supplied accessories

 

Matching connectors for control inputs / outputs. 

 

Optional accessories

 

Instruction manual 

 

CPS-1210 10 button local control panel kit. 

 

CPS-1220 20 button local control panel kit. 

 

CPS-1050 10 button remote control panel. 

 

CPS-1052 20 button remote control panel. 

 

GDW-1050 10 way HE14 to D25 male adapter cable to connect remote 
panel to switcher. 

 

Due to our policy of continuing development, these specifications are subject to change without notice. 

Содержание AVS-1210

Страница 1: ...AVS 1210 I R T Communications Pty Ltd www irtcommunications com Revision 06 User Manual 10 x 1 Video Switcher...

Страница 2: ...400 10x1 switchers manuals S N 9910000 02 06 12 1999 AJP Front and rear panel diagrams added S N 9910000 03 07 03 1997 AJP Warning note on PL 4 to PL 5 connection added S N 9910000 04 12 09 2001 SH IR...

Страница 3: ...l Description 7 Internal adjustments 9 Configuration 9 Wire per crosspoint control 10 Tally outputs 11 Audio breakaway 12 Configuration examples 13 Configurations for up to 200 x 1 14 Installation 15...

Страница 4: ...ons dangerous potentials may exist in some circuits when power controls are in the OFF position Maintenance personnel should observe all safety regulations Do not make any adjustments inside equipment...

Страница 5: ...ral switchers to be stacked with common inputs without the need for additional distribution amplifiers The switcher is housed in an IRT one rack unit 44 mm high 483 mm 19 inch rack mounting metal chas...

Страница 6: ...rval Timing is derived from the output video Type 4 5 bit parallel TTL level signal compatible with IRT VA 400 video switcher tally output circuit and IRT 3000 series switchers Number 1 input 1 output...

Страница 7: ...ff isolation in the disabled state and fully buffered unilateral signal path Make before break switching assures virtually glitch free switching For use in N x M routing matrices the GX4314 features v...

Страница 8: ...h in Unlatch out The 5 bit codes on Pins 2A to 4A represent the input selected This code is in BCD Binary Coded Decimal where the Data 0 to 3 represent the binary numbers 0 to 9 Inputs 1 to 10 if Data...

Страница 9: ...ntrol panels under Installation PL 4 on the control panel is then connected to PL4 on the rear of the switcher PL 5 on the control panel is then connected to the switcher PCB 20 x 1 operation A link i...

Страница 10: ...quired it is not possible to operate the switcher in 20 x 1 wire per crosspoint mode and retain the standard BCD remote control For 20 x 1 operation it is necessary to wire connections from the back o...

Страница 11: ...W 10 10 6A 5 Vdc 11 6B 12 7A No connection 7B 8A 8B 20 x 1 Operation Due to the number of connections required it is not possible to operate the switcher in 20 x 1 wire per crosspoint mode and retain...

Страница 12: ...This option is available either by using two interconnected CPS 1050 10 button remote control panels one CPS 1052 20 button remote control panel or one AVS 1210 10 x 1 video switcher fitted with a CP...

Страница 13: ...4 10 way ribbon cable to D25 male CPS 1052 20 button remote control panel Optional additional panels 25 way ribbon cable male D to male D 25 way ribbon cable male D to male D 25 way ribbon cable male...

Страница 14: ...ections for video and audio signal wiring between the input switchers and the bank control switcher are required Please consult IRT for details of connections before proceeding See also Configuration...

Страница 15: ...wer AC mains supply Ensure that operating voltage of unit and local supply voltage match and that correct rating fuse is installed for local supply DC supply Ensure that the correct polarity is observ...

Страница 16: ...e OUT For switch panel to operate as tally only LK 3 should be in position A For front panel switches to be operative LK 3 should be in position B 6 Fit new front escutcheon using the original 6 screw...

Страница 17: ...r the 11 20 switch PCB LK 2 should be OUT For switch panel to operate as tally only LK 3 should be in position A on both PCB s For front panel switches to be operative LK 3 should be in position B on...

Страница 18: ...pin D sockets on the rear panel The connections to PL 4 PL 5 are 1 14 12 Vdc for remote control panel PL 4 only 2 15 Gnd 3 16 Switch pulse 4 17 5 18 D Data 3 6 19 C Data 2 7 20 B Data 1 8 21 A Data 0...

Страница 19: ...l and either the AAS 1220 or AVS 1210 The two switchers are then linked with a 25 way cable wired pin to pin Note that he connection must always be from PL 5 on the remote control panel to PL 4 on the...

Страница 20: ...tion 20 x 1 operation For 20 x 1 operation LK 2 should be installed For normal operation it must not be installed While LK 2 is installed the switcher will respond to commands for crosspoints 11 20 as...

Страница 21: ...itted with CPS 1210 front view CPS 1210 view of rear from inside chassis AVS 1210 fitted with CPS 1220 front view CPS 1220 view of rear from inside chassis CPS 1210 view of rear from inside chassis co...

Страница 22: ...nty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and n...

Отзывы: