The Special Functions

dial position provides access

to various control features and optional display formats.
The special functions are: Water Budget, Station Run
Time Duration Format Option, Display Language Option,
Clock Time Format Option, Program Erase and
Enable/Disable Expansion Port.

Water Budget enables you to conveniently decrease or
increase the run time duration currently set for each
station assigned to a selected program. The adjustment
can be made in 10% increments from 0% (program Off)
to 200% of the normal (100%) run time.

Note: Water Budget is applied to programs A, B and C
independently. For example, applying Water Budget to
program A will not alter the run time duration of any
stations assigned to Program B or C.

1. Turn control dial to the Special Functions

position. 

2. Press the 

button as needed to select the desired

program. The currently set percentage for the
program will be displayed. 

3. Press the 

or 

button to select the desired

adjustment percentage; i.e., 90% equals a 10%
reduction of station run time and 200% doubles the
station run time.

4. To apply Water Budget to another program, repeat

steps 2 and 3.

5. Turn control dial to the Auto

position when finished.

Note: During operation, the display will show the
adjusted run time for each station as it starts running.

As a reminder of Water Budget setting (other than 100%),
the symbol will be displayed with the current time. 
See “Important” on page 8 for additional information. 

The station run time duration can be displayed in either
minutes or hours and minutes format. To change the
current run time format, use the following procedure:

1. Turn the control dial to the Special Functions position.

2. Press the 

button as needed to display MMM or

HH:MM.

3. Press the 

or 

button to select the desired

format:

MMM = minutes; i.e., 1 hour and 30 minutes is
displayed as 90M.

HH:MM = hours and minutes; i.e., 1 hour and 30
minutes is displayed as 1:30.

4. Turn control dial to the Auto

position when finished.

Various display information can be viewed in any of five
languages: English, Spanish, French, German or Italian.
To change the display language, use the following
procedure:

1. Turn control dial to the Special Functions

position.

2. Press the 

button as needed to display ENG.

3. Press the 

or 

button to select the desired

language: ESP (Spanish), FRA (French), ITA (Italian)
or DEU (German).

4. Turn the control dial to the Auto

position when

finished.

Display Language Option

Station Run Time Duration Format Option

Water Budget

Special Functions

Содержание KwikDial

Страница 1: ...ring Schedule by 7 Day Calendar Day Interval or Odd Even Days Three Start Times Per Program Multi language Display Option 24 hour Memory Back up Without Battery Automatic Valve Testing Mode Rain Delay...

Страница 2: ...50 60 Hz 20 VA Indoor Models Export Plug in Transformer TUV Approved Input 230 V a c 50 Hz 0 1 Amps Output 24 V a c 50 Hz 20 VA Outdoor Models Export Built in Transformer TUV Approved SAA Approved Inp...

Страница 3: ...Day Interval Schedule 12 Setting Program Start Time 12 Setting Station Run Time Duration 13 Controller Operations 13 15 Automatic Operation 13 Manual Operations 13 True Manual Operation 14 Timed Manua...

Страница 4: ...unctions 7 Button Press to select program A B or C 8 Button Press to advance to next portion of program information or next station when operating 9 Station Terminals Connection terminals for valve co...

Страница 5: ...3 3 1 2 3 4 5A 5B 5C 6 7 8 9 19 18 10 15 14 13 12 11 16 17 20 Note Power connection access cover removed for illustration International Models See Troubleshooting...

Страница 6: ...the sides and pulling it directly outward from the cabinet 4 Hang the cabinet on the screw using the keyhole slot on the back panel B Make sure the cabinet slides down securely on the screw 5 Install...

Страница 7: ...station terminals Connect the master valve wire if applicable to the terminal labeled MV Note Connecting a master valve or pump start relay is optional and may not be required for your sprinkler syst...

Страница 8: ...cm of the transformer wire cable into the controller through the small opening provided in the base of the cabinet 2 Tie a knot in the cable just inside the cabinet to prevent the cable wires from pu...

Страница 9: ...be displayed for 30 seconds while the program memory back up power is being charged During this time the controller can not be operated This will only occur when the controller is initially powered up...

Страница 10: ...Interval schedule indicate the desired Interval number 1 31 For Odd or Even day watering schedule simply mark the appropriate box Station Run Time Duration Indicate the amount of run time 1 minute to...

Страница 11: ...Odd Even Odd Even Station Location Run Time Run Time Run Time Program A Program B Program C Example Parkway Lawn 10 min Off Off Front Lawn 10 min Off Off Front Shrubs Off 5 min Off Back Lawn 25 min Of...

Страница 12: ...10 Program Start Times Watering Day Schedule Day Interval Calendar Days Odd Odd Even Even 1 2 3 Odd Even Odd Even Station Location Run Time Run Time Run Time Program A Program B Program C...

Страница 13: ...the no watering symbol is displayed for the selected program 4 Repeat steps 1 and 3 for each day of the week 5 Repeat steps 1 4 for each program as needed 6 Turn the control dial to the Auto position...

Страница 14: ...Turn the control dial to Auto position when finished Note To prevent watering on specific days of the week regardless of schedule type i e never water on Saturday turn the control dial to that day an...

Страница 15: ...l dial to Auto position when finished The KwikDial controller has five modes of operation Automatic Manual Station s Manual Programs Test and Off In the Automatic mode the controller tracks the time a...

Страница 16: ...2 4 to select additional stations These stations will not start immediately but will operate in sequence 6 After all desired stations for timed manual operation have been selected turn control dial to...

Страница 17: ...in sequence starts By leaving the dial in the Auto position the controller completes the test of each station then returns to the Automatic mode To manually advance to the next station in sequence pre...

Страница 18: ...ol dial to the Auto position when finished Note During operation the display will show the adjusted run time for each station as it starts running As a reminder of Water Budget setting other than 100...

Страница 19: ...in conjunction with the KwikStart remote system The expansion port provided for the remote receiver connection must be switched On to enable KwikStart remote control operation 1 Turn control dial to...

Страница 20: ...ease adjustment factor as necessary See pages 8 and 16 Troubleshooting 2005 Irritrol Form Number 373 0239 Rev C For Technical Assistance USA 951 785 3623 800 634 8873 Europe 39 0765 40191 Australia 13...

Отзывы: