background image

13

The station run time duration is the amount of time a
station will operate once it has been started. A station is
assigned to a program when it is given a designated run
time duration ranging from 1 minute to 4 hours. Each
station can have a different run time duration in each
program. 

Note: You have the option to view station run time duration
in minutes only or in hours and minutes. By default, the run
time will be displayed in the minutes format; i.e., 1 hour
and 30 minutes is displayed as 90 M (minutes). To select
the alternate format, refer to “Station Run Time Duration
Format Option” on page 16.

1. Turn the control dial to the desired Station

number

position. The selected station number and the station
run time duration symbol

will be displayed.

Note: For KwikDial controllers with more than six
stations, use the 

button to switch from the inner

labeled stations (1–6) to the outer labeled stations
(7–9 or 7–12).

2. Press the 

button as needed to select the desired

program. Program letter Aor will be displayed. 

3. Adjust the station run time duration by pressing the

or

buttons.

• To remove the station from the program, decrease

the run time duration to less than 1 minute to 
display -- -- -- (dashes). 

4. Repeat steps 1 and 3 to set the run time duration for

each station as needed for the selected program.

5. Repeat steps 1–4 for each program as needed.
6. Turn the control dial to Auto

position when finished.

The KwikDial controller has five modes of operation:
Automatic, Manual Station(s), Manual Programs, Test
and Off. In the Automatic mode, the controller tracks the
time and day and operates the automatic watering
schedules as programmed. The Manual Station(s) mode
enables an individual station or group of stations to be
started and controlled manually. Manual Programs mode
enables watering programs to be started manually. Test
mode enables a quick, temporary program to be run to
test the operation of each station control valve. The Off
mode prevents all station operation.

Automatic operation will occur whenever the
programmed start time and watering day matches the
KwikDial’s internal clock and calendar.

The Auto

control dial position is the normal position

for the dial when automatic operation is desired.
However, the controller will operate automatically when
the control dial is in any position other than Off

.

While an automatic watering program is running and the
control dial is in the Auto

position, pressing the 

button will manually advance from the activate station to
the next displayed station number in sequence 

Manual controller operations will override all currently
active automatic operation and sensor input. Any
automatic program start time that occurs during a
manual operation will be delayed until the manual
operation is terminated or concluded. Any automatic
program delayed past midnight will be postponed. 

Manual Operations

Automatic Operation

Controller Operation

Setting Station Run Time Duration

Содержание KwikDial

Страница 1: ...ring Schedule by 7 Day Calendar Day Interval or Odd Even Days Three Start Times Per Program Multi language Display Option 24 hour Memory Back up Without Battery Automatic Valve Testing Mode Rain Delay...

Страница 2: ...50 60 Hz 20 VA Indoor Models Export Plug in Transformer TUV Approved Input 230 V a c 50 Hz 0 1 Amps Output 24 V a c 50 Hz 20 VA Outdoor Models Export Built in Transformer TUV Approved SAA Approved Inp...

Страница 3: ...Day Interval Schedule 12 Setting Program Start Time 12 Setting Station Run Time Duration 13 Controller Operations 13 15 Automatic Operation 13 Manual Operations 13 True Manual Operation 14 Timed Manua...

Страница 4: ...unctions 7 Button Press to select program A B or C 8 Button Press to advance to next portion of program information or next station when operating 9 Station Terminals Connection terminals for valve co...

Страница 5: ...3 3 1 2 3 4 5A 5B 5C 6 7 8 9 19 18 10 15 14 13 12 11 16 17 20 Note Power connection access cover removed for illustration International Models See Troubleshooting...

Страница 6: ...the sides and pulling it directly outward from the cabinet 4 Hang the cabinet on the screw using the keyhole slot on the back panel B Make sure the cabinet slides down securely on the screw 5 Install...

Страница 7: ...station terminals Connect the master valve wire if applicable to the terminal labeled MV Note Connecting a master valve or pump start relay is optional and may not be required for your sprinkler syst...

Страница 8: ...cm of the transformer wire cable into the controller through the small opening provided in the base of the cabinet 2 Tie a knot in the cable just inside the cabinet to prevent the cable wires from pu...

Страница 9: ...be displayed for 30 seconds while the program memory back up power is being charged During this time the controller can not be operated This will only occur when the controller is initially powered up...

Страница 10: ...Interval schedule indicate the desired Interval number 1 31 For Odd or Even day watering schedule simply mark the appropriate box Station Run Time Duration Indicate the amount of run time 1 minute to...

Страница 11: ...Odd Even Odd Even Station Location Run Time Run Time Run Time Program A Program B Program C Example Parkway Lawn 10 min Off Off Front Lawn 10 min Off Off Front Shrubs Off 5 min Off Back Lawn 25 min Of...

Страница 12: ...10 Program Start Times Watering Day Schedule Day Interval Calendar Days Odd Odd Even Even 1 2 3 Odd Even Odd Even Station Location Run Time Run Time Run Time Program A Program B Program C...

Страница 13: ...the no watering symbol is displayed for the selected program 4 Repeat steps 1 and 3 for each day of the week 5 Repeat steps 1 4 for each program as needed 6 Turn the control dial to the Auto position...

Страница 14: ...Turn the control dial to Auto position when finished Note To prevent watering on specific days of the week regardless of schedule type i e never water on Saturday turn the control dial to that day an...

Страница 15: ...l dial to Auto position when finished The KwikDial controller has five modes of operation Automatic Manual Station s Manual Programs Test and Off In the Automatic mode the controller tracks the time a...

Страница 16: ...2 4 to select additional stations These stations will not start immediately but will operate in sequence 6 After all desired stations for timed manual operation have been selected turn control dial to...

Страница 17: ...in sequence starts By leaving the dial in the Auto position the controller completes the test of each station then returns to the Automatic mode To manually advance to the next station in sequence pre...

Страница 18: ...ol dial to the Auto position when finished Note During operation the display will show the adjusted run time for each station as it starts running As a reminder of Water Budget setting other than 100...

Страница 19: ...in conjunction with the KwikStart remote system The expansion port provided for the remote receiver connection must be switched On to enable KwikStart remote control operation 1 Turn control dial to...

Страница 20: ...ease adjustment factor as necessary See pages 8 and 16 Troubleshooting 2005 Irritrol Form Number 373 0239 Rev C For Technical Assistance USA 951 785 3623 800 634 8873 Europe 39 0765 40191 Australia 13...

Отзывы: