Function Dial: 

For selecting programming and operating functions

Water Budget:

For single-entry increase or decrease of watering times for all

stations within a program by a selected percentage (does not alter program)

Program Erase: For erasing programmed information

Options: For selecting additional features, 6-day watering schedule, seconds,

loop and/or hours

Valve Test: For running a valve test for all stations from 1 to 9 minutes

Rain Off: For turning off output to all stations manually or programmable to

7 days off

Manual: For true manual operation

Semi-Automatic Watering: For activating a manual watering cycle that uses
the programmed station watering times

Auto Run: 

Position for automatic operation

Advance Buttons: For programming and operating functions

Digital Display: For viewing time and program information

On/Off Buttons: For programming and operating functions

Program Select Switch: For program selection
Program LEDs: To indicate what program is currently operating

Water Budget Indicator: Shows whether water budgeting for the program
selected is other than 100%

Current Time: For setting current time

Current Day: For setting calendar day

Station Watering Time: For setting individual watering time for each station

All Station Watering Time: For setting watering-time for all stations with
one entry
Watering Day Schedule: For setting which days to water

Watering Start Times: For setting the times each watering cycle will start

Terminal Strip: For hook-up of transformer, valve wires, common wire,
pump start and sensors

Battery 

Snap: For hookup of 9V alkaline battery to keep time during

power failures

12OV/24V  transformer

Short Wire: Must be installed if sensor is not used

16
17

18

Содержание Dial Series

Страница 1: ...D I A L S E R I E S CONTROLLERS OWNER S MANUAL 5 7 11 14 16 18 24 30 and 36 stations q lrritrol...

Страница 2: ...you for purchasing a Dial Series Controller Listed below are some important features you should be aware of before you begin programming Details on how to implement these features are described on the...

Страница 3: ...Advance Buttons For programming and operating functions Digital Display For viewing time and program information On Off Buttons For programming and operating functions Program Select Switch For progr...

Страница 4: ...ng install the controller vertically on a flat secure surface Use the enclosed template to locate mounting screw holes Follow complete mounting instructions on template PEDESTAL For free standing inst...

Страница 5: ...common wire for each controller DO NOT daisy chain controllers together using the same common wire 3 Before turning on the power recheck all leads connected to the terminal block for shorts TESTING TH...

Страница 6: ...included NOTE The controller will not activate valves during a power failure INSTALLING AND USING SENSOR PORTS CAUTION DO NOT attempt to power the controller using power from one phase of pump power T...

Страница 7: ...d by a remote control device such as the RVC system Press both Advance buttons at the same time to clear FUSE is alternately displayed with 0 and none of the stations is operating automatically The ma...

Страница 8: ...number corresponding to the current day appears in the display Programming the Controller for Watering ERASING ANY PRIOR PROGRAMS This process erases all watering times watering start times the water...

Страница 9: ...7 2nd Week 8 9 10 11 12 13 14 CONTINUED 1 Select the desired program A or B 2 Set the dial to the Watering Day Schedule position 3 Press the Advance A or Advance V buttons until the desired day of th...

Страница 10: ...ing CONTINUED CANCELLING A WATERING START TIME 1 Select the desired program A or B 2 Set the dial to the Watering Start Times position 1 2 or 3 3 Press the On A button or the Off V button to select a...

Страница 11: ...ss the On A button The station will water until turned off or until midnight whichever comes first TURNING OFF MANUAL WATERING 1 Press the Off V button or move the dial out of Manual position MANUAL O...

Страница 12: ...oop operation program B only WATER BUDGETING The water budgeting feature allows you to quickly increase or decrease the watering time per program The currently programmed times can be adjusted by a pe...

Страница 13: ...ons to select option 2 3 Press the On A button To return to minutes mode 1 min to 99 mm I Set the dial to the Options position 2 Use the Advance A or Advance V buttons to select option 2 3 Press the O...

Страница 14: ...select station 88 5 Press the On A button or the Off v button to select the delay time 0 minutes to 99 minutes NOTE Station 88 is always in minutes regardless of option 2 and 3 settings 24 Using Adva...

Страница 15: ...controller 5 Press both Advance buttons at the same time to reset Controller 1 Indicates hardware failure Disconnect Displays Err 1 power for 5 minutes If Err is still or Err 2 displayed return for r...

Страница 16: ...ng Watering 16 Stacking Feature 12 Unlimited Loop Watering Y 24 Station 88 Loop Delay 24 Maximum Output 7 Watering Time Setting the 13 Temperature Maximum 4 Terminal Strip 2 Time Setting the Current 1...

Страница 17: ...100 119 ON Wd v Aatl bZ66 L Xl OSOd 13 aA Ja PDOJl W S9b6 GupnpopwDyy m u bE9 008 L 999C6 V3 WB N Dun V PDW ZOd D l LL9LZ s qDdea PUy Se J nbUl 3npOJd...

Отзывы: