ASC (All Station Cycle) Operation
The ASC feature enables all stations to be automatically
operated in numeric sequence for a two-minute run time.
The station run time used during ASC operation is fixed
at two minutes and cannot be adjusted.
When the ASC operation is initiated, a start command is
sent to station number 1. The station runs for two minutes
and shuts off. All subsequent stations will then operate
automatically in numeric sequence.
To adjust the station
number range, refer to the procedure on page 15.
Initiate ASC Operation
1 – Press and hold the
ON button until the
transmitter powers up.
The last station
number operated will be displayed.
2 – To select the ASC function, press the
up arrow button one step past the highest
station number, or press the
down arrow
button one step past the lowest station number.
For
rapid scrolling, press and hold
the button.
3 – Press the
ON button.
Station 1 will turn
on and the timer will begin counting down
from two minutes, in one-second intervals.
Every 15 seconds, the display will alternate
to show the operating station number.
The receiver plug is specifically designed
for the CMR-KIT receiver and must be
installed. Irritrol KwikStart
®
Remote receiver
plug is similar, but is not compatible CMR-
KIT.
12
CMR-KIT
ASC Operation
Irritrol CMR-KIT 10/27/06 10:55 AM Page 12
Содержание CMR-KIT
Страница 1: ...CMR KIT Maintenance Remote User s Guide Installation Setup Operation Service...
Страница 5: ...CMR KIT Transmitter Components 3 1 2 4 3 5 6 9 8 7 G F E D C B A H...
Страница 7: ...CMR KIT Receiver Components 5 1 2 3 4 6 5 8 9 7...
Страница 11: ...CMR KIT Outdoor Installation 9 Figure 3 Figure 2 To Controller...
Страница 24: ...2006 Irritrol www irritrol com Form Number 373 0425 Rev A Site Reference Record...