background image

EcoZone Mobile App Connects to Controller  

via IrriGreen Private Wi-Fi Network  

Look for IrriGreen Wi-Fi network with your mobile device 

 

No internet connection needed 

IrriGreen private Wi-Fi signal from Controller   

Wi-Fi Range: 

Controller location, height, landscape 
elevations (signal going through dirt), house 
construction (stucco, etc.) will affect Wi-Fi 
range. Use Wi-Fi extender such as Linksys 
AC750 to extend range while mapping zones.  

Note: 
No need to log onto 
property owner’s 
Wi-Fi network 

15 

Содержание EcoZone ConServer

Страница 1: ...EcoZone Installation Manual Waterproof Plug n Play Cables 16 4 EcoZone ConServer Genius Sprinkler 2 0 with EcoZone Technology Installation Video Irrigreen com professionals logged in Password goirrigreen 2 0 5 1 ...

Страница 2: ... Wi Fi connection and Range App connects to IrriGreen Wi Fi network 15 Controller and Server communication Connect to each other via radio 16 Controller and Server power 24VAC 17 EcoZone Plug n Play Cables w CableLok Waterproof cables simplify installation 18 19 Valve Box Installation Always protect connections with valve boxes 20 Mater Valve and Pump Wiring IrriGreen recommends master valves 21 S...

Страница 3: ...inkler 2 0 1 per zone 2000 sq ft Wi Fi Controller Private Wi Fi EcoZoneTM Server 20 Zones 16 EcoZones 4 standard valves 1 master Indoor Transformer 24 VAC 20VA 1 Flow Sensor 3 EcoZone ConServer TM Package Cable Tee w end plug Sprinkler Cable 50ft CableLok FlexPipe 15 in ...

Страница 4: ... lengths for Flow Sensor Small valve box Use for Flow Sensor and for EcoZone Cable connections Grease cap wire nut connectors for Flow Sensor 3M DBY R Orbit 57002 or similar 1 Tees PVC or poly Elbows PVC or poly Two strand transformer and flow sensor wire 4 ...

Страница 5: ...ressure between 40 80 psi 10 gpm 1 mainline Well systems require a constant pressure pump or regulated constant pressure supply e g with a PRV set below the lowest pump setting Filter needed for any water source with particulates sand grit 500 Micron filter similar to drip systems recommended 5 ...

Страница 6: ...cing heads Low flow may affect throws Maximum Throw 40 psi 25 50 psi 27 5 60 psi 30 70 psi 32 5 80 psi 35 Minimum Throw 40 psi 5 50 psi 5 60 psi 5 70 psi 5 80 psi 5 6 Total Area At 60 psi one IrriGreen Genius head will evenly water up to 2000 sq ft ...

Страница 7: ...to the shape of the zone Don t overlap sprays or zones Installation hint Walk in from the corner with a wheel and place a flag at 25 30 for head placement NOTE The zone start up point Position 1 must be set at least 10 feet so the head has enough flow pressure to fully pop up After head is fully popped up OK to set points as short as 5 feet 7 ...

Страница 8: ...e head 5 feet or more from the nearest edge For narrow zones less than 10 wide place head along edge and program in a 180 degree pattern Design hint For watering shrubs bushes without drip program streams to shoot out and hit individual bushes 8 ...

Страница 9: ...g Server Cable Connects Server to the first Sprinkler Sprinkler Cable Connects Sprinklers FlexPipe plumbs Mainline to Genius Sprinkler 1 PVC 24 and 24 lengths for Flow Sensor Sprinkler s are pre numbered with Zone Numbers 1 8 9 16 ...

Страница 10: ... Number numerical order Locate each sprinkler in the numerical order you want them to run 10 EcoZone Sprinklers have Zone Numbers 1 8 9 16 assigned at the factory Zone Number on Sprinkler box Zone Number on Sprinkler Head 1 runs first Head 2 runs second Head 3 runs third Etc ...

Страница 11: ...installing any heads flush lines to remove all dirt and sand 2 After all heads are installed run the last Genius sprinkler s on the line at maximum throw for several minutes to remove all air from the system Trapped deadhead air will cause calibration errors 11 ...

Страница 12: ...12 ...

Страница 13: ...Genius Head Depth Position head so the Genius sprinkler cap is slightly above grade 13 ...

Страница 14: ...14 Sprinkler s are pre numbered with Zone Numbers 1 8 9 16 ...

Страница 15: ...net connection needed IrriGreen private Wi Fi signal from Controller Wi Fi Range Controller location height landscape elevations signal going through dirt house construction stucco etc will affect Wi Fi range Use Wi Fi extender such as Linksys AC750 to extend range while mapping zones Note No need to log onto property owner s Wi Fi network 15 ...

Страница 16: ...Controller Server Communicate Wirelessly up to 150 Install at least 6 apart They communicate via 433 Mhz radio separate from the IrriGreen Wi Fi network 16 ...

Страница 17: ...Controller Server Power 24 VAC 20 VA Piggyback Wiring Two transformers optional 17 ...

Страница 18: ...o be changed see Advanced Zone Address instructions Daisy chain up to eight Genius Sprinklers per Server Cable Sprinklers are pre numbered with Zone Numbers 1 8 9 16 End Plug seals the open plug for the last sprinkler in line End Plugs are supplied with each Server Cable and Cable Tee ...

Страница 19: ...19 Install on all EcoZone Cable connections ...

Страница 20: ...Waterproof EcoZone Cable Connections All connections should be protected by a small valve box Install next to Genius head below turf Install box below turf 20 ...

Страница 21: ...21 Master Valve Recommended for all Systems Master Valve Wiring EcoZone systems relieves mainline pressure by opening a Genius Sprinkler 2 0 valve briefly after the last EcoZone watering event ...

Страница 22: ...22 If Pump relay is installed in addition to the Master Valve a Pump Start Relay Booster may be needed ...

Страница 23: ...cturer to eliminate turbulence at sensor 23 Flow sensor unscrews from the saddle tee When reassembling make sure to seat sensor properly on the tee alignment pin Glue Carefully Remove sensor before gluing pipe Glue on the sensor paddles will cause inaccurate readings and calibration errors 24 1 PVC 24 1 PVC ...

Страница 24: ...it 57002 or similar grease cap with wire nut connectors Push wire nut all the way into gel cap ensure wires and wire nut are totally sealed by gel Remember Unsheathed multi color wire is not rated for or meant for direct burial Even very small nicks or cracks in multi color wire insulation will cause ground faults data errors 24 ...

Страница 25: ...Connect Normally Closed NC wires to Sensor 1 and Common right side Server terminals Turns the system off when sensor is activated Connect Sensor Normally Closed NC wires to Sensor 1 and the Common terminal ...

Страница 26: ...es Streams Not Evenly Spaced Make sure green cap is tight Line up filter marks with nozzle opening Clean change filter nozzle Check filter if streams not tracking evenly Make sure filter markings line up with nozzle opening 26 ...

Страница 27: ...move all air from the system Also check for glue on the flow sensor impeller 27 1 Check Server wiring tighten terminals 2 During EcoZone Activation make sure only one non activated Sprinkler is connected at a time Disconnect any extra Sprinklers 3 During EcoZone Activation make sure to select the next EcoZone Sprinkler number on the Server Page before activating the new Sprinkler If the same numbe...

Страница 28: ... a problem Follow troubleshooting list on screen Valve Ball valve in sprinkler not operating properly Rotor Rotor drive in sprinkler not operating properly Controller Controller not communicating with the mobile app Server Server not communicating with the Controller 28 ...

Страница 29: ... FCC 15 21 The user and installer of the IrriGreen Genius Irrigation System shall not make any modifications to the system not expressly approved by IrriGreen Unauthorized modifications will void the warranty and void the user s authority to operate the equipment per FCC rules 29 Wi Fi Range Controller location height landscape elevations signal going through dirt house construction stucco etc wil...

Отзывы: