background image

19

REPLACEMENT PARTS - MODELS C160 AND CA160

FRONT DOOR PARTS LIST

Item #

Cat. No

Description

1

H5639

Door Rope Kit, 7/8” Dia. (6’ 2”)

2

H5629

Upper Hinge Pin

3

H5625

Upper Hinge Pin E-Clip

4

H5628

Lower Hinge Pin

5

H5646

Lower Hinge Pin Copper Washer

6

H5640

Glass Gasket Kit (8’ 4”)

7

H5577

Set of 6 screws and 6 washers for door assembly

8

H5654

Spring Handle / Nickel

H5653

Spring Handle / Gold

9

71067

Traditional Door Glass / Plain

71068

Traditional Door Glass / Sailboat

71063

Traditional Door Glass / Cattail

71065

Traditional Door Glass / Evergreen

71066

Traditional Door Glass / Floral

10

71057

Traditional Door Faceplate / Black

71058

Traditional Door Faceplate / Gold

71059

Traditional Door Faceplate / Nickel

71148

Traditional Door Faceplate / Brushed Gold

71145

Traditional Door Faceplate / Brushed Nickel

11

71072

Arch Door Glass / Plain

71073

Arch Door Glass / Sailboat

71069

Arch Door Glass / Cattail

71070

Arch Door Glass / Evergreen

71071

Arch Door Glass / Floral

12

71060

Arch Door Faceplate / Black

71061

Arch Door Faceplate / Gold

71062

Arch Door Faceplate / Nickel

71147

Arch Door Faceplate / Brushed Gold

71144

Arch Door Faceplate / Brushed Nickel

13

H5579

Traditional Door Back w/ Handle (door gasket 

included)

14

H5578

Arch Door Back w/ Handle (door gasket included)

USB BLOWER PARTS

Item #

Cat. No

Description

15

H8067

UHPII Wiring Harness

16

H5655

UHPI & UHPII Blower Speed Control

17

H8068

Snap Switch Bracket w/ hardware

18

H8082

Replacement Power Cord

19

H8074

UHPII Blower Cage-Snap Switch/ Black

H8075

UHPII Blower Cage-Snap Switch/ Gold

H8076

UHPII Blower Cage-Snap Switch/ Nickel

H8077

UHPII Blower Cage-Snap Switch/ Brushed Gold

H8078

UHPII Blower Cage-Snap Switch/ Brushed Nickel

29

H8064

Snap Switch w/ Gasket and Screws

32

H8066

Control Switch (Manual, Off, Automatic)

C160 AND SWI160 INSERT PARTS

33

71138

Small Flange Screw/ Black - Seven Needed

71127

Small Flange Screw/ Gold - Seven Needed

71128

Small Flange Screw/ Nickel - Seven Needed

34

F1871

IronStrike™ Nameplate Kit w/ Hardware - Nickel 

F1872

IronStrike Nameplate Kit w/ Hardware - Gold

35

H5650

Draft Rod Knob

36

H5647

Tinnerman Nuts for Flange Installation - Seven 

Needed

37

H5645

Side Leveling Bolts - Two Included

38

H5644

Blower Mounting Bolts - Two Needed

39

H5612

Firebrick 4-1/2” x 9” (10 per appliance)

40

H5576

Firebrick 4-1/4” x 9” (2 per appliance)

41

H5607

Firebrick 2-1/4” x 9” (3 per appliance)

42

H3095

Firebrick 2-1/4” x 8-7/8” (1 per appliance)

43

H5604

Firebrick 1-1/2” x 9” (1 per appliance)

44

H5597

Firebrick 1-1/2” x 8-7/8” (1 per appliance)

45

H3104

Front Baffle/Secondary Burn Tube Assembly

46

H3105

Middle/Rear Baffle/Secondary Burn Tube Assembly

47

H3103

Complete Baffle/Secondary Burn Tube Assembly 

(includes tubes and all mounting hardware) 

48

H8017

Baffle Blanket 20” x 11” x 1” 

49

H8016

Baffle Board Kit w/ Baffle Blanket

MISCELLANEOUS PARTS

---

71052

Dry Graphite (Apply to door handle and door hinges)

---

H5633

Anti Seize 2 gram pouch

Contact an IHP dealer to obtain any of these parts. Never use 

substitute materials. Use of non-approved parts can result in 

poor performance and safety hazards.

Содержание Striker C160

Страница 1: ...éro de la pièce 900100 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before installing and using your wood fireplace insert Failure to followtheseinstructionscouldresultinpropertydamage bodilyinjury orevendeath Contactyourlocalbuildingorfireofficialstoobtain a permit and inform...

Страница 2: ...arth Protection 8 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE Chimney Requirements 9 Installation Procedure Masonry Chimney 9 Positive Flue Connection 10 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fire...

Страница 3: ...heburn ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a hot fire If large ac cumulationsareoccurring reviewyourburningprocedures 14 Ifacreosotefireshoulddevelop thefiredepartmentshould be called immediately and then attempts should be made to cont...

Страница 4: ...ay include Cracking warping or burning out of components plated accessories may turn color stove glass may develop a haze which will not come off with cleaning Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached beyond the design capabilities of the appli ance The damage that occurs from overfiring is not covered under the manufacturer s limited warran...

Страница 5: ...heater In well insulated and weather tight homes it may be difficult to establish a good draft up the chimney caused by a shortage of air in the home The lack of air is caused by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also the combustion process of this heat...

Страница 6: ... The final step of the baffle board baffle blanket installation will be installing the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffle boards of the four baffle board kit They will be installed with the 7 3 8 dimension from the front to rear of the firebox Start by setting the back side of the board on the rear baffle making sure ...

Страница 7: ...to the side 8 200mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector This appliance may be installed in a bedroom in the United States Model A B C D E 1 C A160 USA 24 CAN 660mm USA 15 CAN 450mm 20 508mm 12 305mm USA 4 1 2 CAN 200mm C A160 with mantel and or side shields 16 406mm...

Страница 8: ...ken from Tables 2 and 3 Using the k formula FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 375 84 156 inches 417 x 375 Answer TheminimumrequiredthicknessoftheMicore1...

Страница 9: ...are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround panels and level the fireplace insert with the leveling bolts using a 3 4 19 mm socket extensions to reach the bolt head and a ratchet 8 Glue the insulation around the outer edge of both the top and side surroun...

Страница 10: ...l off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustible material i e high temp fiberglass or ceramic insulation around the vent pipe or using a flue adapter Whatever seal off method is used it must effectively seal the area to prevent room air passage to the chimney cavity of the fireplace Offset Boxes Offsets can be ...

Страница 11: ...3 76 mm long bolts with the head up through the nuts attached to the insert on the lower rear corner of each side This will allow you to level the insert when placed into the fireplace Measure from the front of the top surround mount to the center of the flue Determine if there is an alignment problem in connecting a liner from the chimney to the insert s flue If there is an alignment problem conn...

Страница 12: ...UR INSURANCE COMPANY Chimney Liner Installation Place the insert into the fireplace making sure to center it side to side Slide the insert in until the surround mounts are approximately 1 2 13 mm from the face of the fireplace where the surround panels cover Lower the chimney and make attachment to the insert Level the fireplace insert by using a 3 4 socket and a long extension and adjusting the b...

Страница 13: ...ed while the front door is slightly open Once kindling is burning well larger pieces of wood may be added then the door should be fully closed if there was the need to keep it slightly open during start up DO NOT LEAVE THE APPLIANCE UNATTENDED WHILE THE FRONT DOOR IS SLIGHTLY OPEN CAUTION Do Not alter the adjustment range of the draft control for increased firing for any reason Operate only with f...

Страница 14: ...clockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch TWO S MANUAL WHT NOTE SWITCH CONDITIONS GIVEN AT ROOM TEMPERATURE N C NORMALLY CLOSED N O NORMALLY OPEN FEMALE DISCONNECT MALE DISCONNECT STUD CONNECTION TWO POSITION SWITCH MANUAL TEMPERATURE AUTO RES TEMPERATU SWITCH N POWER CORD RED RED YLW BLK WHT GRN NOTE SWITCH CONDITIONS GIVEN AT ROOM TEMPERATURE N C ...

Страница 15: ... down to 275 to 400 degrees on Elite inserts locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood All IHP stoves and fireplace inserts are EPA tested for emissions at low burn with the air control completely closed Whether or no...

Страница 16: ...e E clip from the upper hinge pin Remove upper hinge pin by pulling up while holding the op posite side of the door Lift door out of the lower hinge pin and place face down on a soft surface Step 2 Remove Door Back Screws 6 ea Using a 5 32 allen wrench remove the 6 retainer screws from the faceplate To locate screws peel back the door gasket as necessary Step 3 Disassemble Door Assembly Flip door ...

Страница 17: ...ve and Clean Glass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote See Creosote section on Page 5 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed fur...

Страница 18: ... the baffle assembly DO NOT Close the door tightly during Burn In period DO Be sure to clean any fingerprints from optional accessories that have plated surfaces before burning the appliance Clean the plated surfaces only with household type glass cleaner and a very soft cloth DO Consult local building department if other than recommended clearances are desired DO Read instructions for the baffle ...

Страница 19: ...placement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Screws 32 H8066 Control Switch Manual Off Automatic C160 AND SWI160 INSERT PARTS 33 71138 Small Flange Screw Black S...

Страница 20: ...20 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts ModelS C160 and CA160 ...

Страница 21: ...21 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 Replacement Parts ModelS C160 and CA160 Door Parts Blower Parts ...

Страница 22: ...3 4 x 40 71079 WFT2948 N Nickel 30 3 4 x 48 BLOWERS Cat No Model Description H7907 WSINS BLWR B SS Blower Insert Black H7908 WSINS BLWR G SS Blower Insert Gold H7909 WSINS BLWR N SS Blower Insert Nickle H7910 WSINS BLWR BN SS Blower Insert Brushed Nickel H7911 WSINS BLWR BG SS Blower Insert Brushed Gold ETCHED GLASS 71073 Glass Arch Sailboat Arch Sailboat 71069 Glass Arch Cattail Arch Cattail 7107...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL ModelS C160 and CA160 2013 2014 2015 Innovative Hearth Products LLC 1508 Elm Hill Pike Suite 108 Nashville TN 37210 ...

Страница 24: ...24 NOTES ...

Страница 25: ...g a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting f...

Страница 26: ...ance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this system please contact your dealer Innovative Hearth Products LLC IHP 1508 Elm Hill Pike Suite 108 Nashville TN 37210 www IronStrike us com Pro...

Отзывы: